©2015 Hestan Commercial Corporation 

 

       

 

Owner’s Guide

 

                                                         Installation & Operation

 

 
 

French Top  

HFT Series 

 

 

 
 

 
 

 

Hestan Commercial Corporation 

            3375 E. La Palma Ave 

           Anaheim, CA 92806 

           (888) 905-7463 

           RETAIN THIS MANUAL FOR FUTURE REFERENCE 

 

P/N 002131 REV 1 

 

Содержание HFT Series

Страница 1: ...ercial Corporation 1 Owner s Guide Installation Operation French Top HFT Series Hestan Commercial Corporation 3375 E La Palma Ave Anaheim CA 92806 888 905 7463 RETAIN THIS MANUAL FOR FUTURE REFERENCE...

Страница 2: ...L GAS SUPPLIER IMPORTANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GAS...

Страница 3: ...r Installation 5 Statutory Regulations 5 United States of America 5 Canada 5 Gas Supply 6 Gas Pressure Regulator 7 Ventilation Air Flue Connections 7 Electrical Supply 8 Model Serial Rating Plate Loca...

Страница 4: ...nd clear of combustible materials Clearances The following minimum clearances must be followed COMBUSTIBLE NON COMBUSTIBLE Model BACK SIDE BACK SIDE French Top 4 4 0 0 NOTE For use on non combustible...

Страница 5: ...allation of this appliance must be carried out by a properly trained and qualified installer and in accordance with the relevant regulations codes of practice and the related publications of the Count...

Страница 6: ...olation valve is fitted or the automatic system can be reset this notice must be posted ALL DOWNSTREAM BURNER AND PILOT VALVES MUST BE TURNED OFF PRIOR TO ATTEMPTING TO RESTORE THE SUPPLY AFTER EXTEND...

Страница 7: ...water solution Do not use an open flame After piping has been checked for leaks all piping receiving gas should be fully purged to remove air Ventilation Air Flue Connections The following notes are i...

Страница 8: ...de Appliances equipped with a flexible electrical supply cord are provided with a three prong grounding plug It is imperative that this plug be connected into a properly grounded three prong receptacl...

Страница 9: ...operation 2 When gas is present turn the knobs to the OFF position Using a log lighter light the pilot s The pilot s can also be lit through pilot viewing holes 3 Wait 3 minutes turn all of the burne...

Страница 10: ...o not spray on due to open flame from pilot lights Apply cleaners with sponge or cloth heavy soil can be removed with a plastic cleaning pad or scraper Wipe surfaces with clean damp cloth to remove so...

Страница 11: ...ted or dirty Vent plugged on regulator or regulator installed improperly Negative pressure or unbalanced ventilation in kitchen creating drafts Low gas pressure to unit Slow to heat up not recovering...