72
-
■ Start Time of Each Block
Assuming that the absolute time of a Point Cloud Data Packet is t0, the start time of each block (i.e., the time when the first firing starts) can be
calculated.
Single Return Mode
Block
Start Time (μs)
Block 8
t0 + 5.632
Block N
t0 + 5.632 - 50 * (8 - N)
Block 3
t0 + 5.632 - 50 * 5
Block 2
t0 + 5.632 - 50 * 6
Block 1
t0 + 5.632 - 50 * 7
Dual Return Mode
Block
Start Time (μs)
Block 8 & Block 7
t0 +5.632
Block 6 & Block 5
t0 + 5.632 - 50 * 1
Block 4 & Block 3
t0 + 5.632 - 50 * 2
Block 2 & Block 1
t0 + 5.632 - 50 * 3
■ Firing Time Offset of Each Channel
Assume that the start time of Block m is T(m), m ∈ {1, 2, ..., 8}, then the laser firing time of Channel n in Block m is
t(m, n) = T(m) + Δt(n), n ∈ {1, 2, …, 16}.
In each round of firing, the firing sequence is from Channel 1 to Channel 16. The firing time offset in units of μs:
Δt(n) = 3.024 * (n-1) + 0.368