64
-
Symptoms
Points to Check
Abnormal packet size
(missing packets)
Verify that
·
horizontal FOV is properly set on the Azimuth FOV page of web control
·
motor's spin rate is steady on the Home page of web control
·
Lidar's internal temperature is between -20℃ and 95℃ on the Operation Statistics page of web control
·
Ethernet is not overloaded
·
no switch is connected into the network. The data transmitted from other devices may cause network
congestion and packet loss
Afterwards,
·
connect the PC only to the lidar and check for packet loss
·