background image

Page 4

HERZ ETKF

Configuration menu

The configuration menu can be used to modify settings. To access this menu, press and hold down the menu button (for 

more than 3 seconds).

•  Pro: For setting the weekly program (see Section “1 Setting the weekly program”)

•  dAt: For modifying the time of day and date

•  POS: For querying the actuator’s current position

•  dSt: Automatic switchover at the start or end of daylight saving time can be deactivated.

•  AEr: For setting the “window open” temperature and time so that the temperature is automatically reduced in the event  

 

of ventilation

•  tOF: For setting the offset temperature

•  rES: For restoring the factory settings

•  UnL: For teaching out all taught-• in wireless components

Use the setting wheel to select menu items and the OK button to confirm your choice. Press the menu button again to return 

to the previous level. After 65 seconds without anything happening, the menu will close automatically.

Display content during normal operation

During normal operation, the following are displayed: day of the week, time of day, date, operating mode, 

temperature setting and switching periods. The bars indicating the weekly program’s switching periods 

are shown for every other time interval. For an example, please refer to “2. Weekly program: Examples”.

Teaching in wireless components

The actuator supports the teaching in of up to 4 system components (e.g. remote control and window contact), plus 1 wall 

thermostat.

•  Press and hold down the OK button for more than 3 seconds.

•  The remaining teach-in time will be displayed (30 seconds).

•  The device being taught-in now needs to send a wireless signal (e.g. press button on remote control).

•  The display will then switch to the normal view.

Once this has been done, the actuator will respond to wireless commands from taught-in devices. Whenever the actuator 

receives a signal from a window contact or remote control, the display will light up briefly.

Teaching out wireless components

Components that have been taught in on the actuator can be taught out again using the “UnL” (Unlearn) function. All wire-

less components are taught out at once with this function.

•  Press and hold down the menu button for more than 3 seconds.

•  Use the setting wheel to select the “UnL” menu item.

•  Confirm with OK.

•  “ACC” will appear on the display; press OK to confirm.

Setting the holiday function

If you want a fixed temperature to be maintained for a set period of time while you are on holiday or during a party, you can 

make use of the Holiday function.

•  Press and release the menu button repeatedly until the suitcase symbol ( ) appears on the display.

•  Use the setting wheel to set the end of the time period during which the temperature is to be maintained.

•  Press the OK button to confirm.

•  Then use the setting wheel to set the date.

•  Press the OK button to confirm.

•  Use the setting wheel to set the temperature; press OK to confirm. The display will flash to confirm your settings.

The set temperature will remain in force until the specified time. After that, the actuator will adopt Auto mode. Wireless 

commands from the window contact and remotecontrol will continue to be executed.

Comfort and set-back temperatures

The comfort/set-back temperature button ( ) provides an easy and convenient way of switching between these two 

temperatures. The factory settings are 21.0°C and 17.0°C respectively. To adapt them, proceed as follows:

•  Press and hold down the comfort/set-back temperature button ( ) for more than 3 seconds.

•  The sun symbol ( ) will appear on the display along with the current comfort temperature.

•  Use the setting wheel to modify the temperature; press OK to confirm.

•  The moon symbol ( ) will appear together with the setback temperature.

•  Use the setting wheel to modify the temperature; press OK to confirm.

The temperature can even be modified in Auto mode at any time by using this button. The new setting will be retained until 

the program’s next switching time.

Child-proof lock/Operating inhibit

Operation can be inhibited.

•  To activate/deactivate the operating inhibit, briefly press the Menu and ( )

 

buttons at the same time.

•  Once the function is active, “LOC” will appear on the display.

•  To deactivate the function, press both buttons again.

Содержание ETKF 1 8250 02

Страница 1: ...iver frequency 868 3 MHz max surrent consumption 100 mA Ambient temperature 5 C bis 55 C max surface temperature 90 C of radiator linear stroke 4 2 mm Application The actuator can be installed on all HERZ TRVs with M28x1 5 Function Thisenergysavingcontrollerforradiatorscanbeusedtocontrolroomtemperatureanthebasisoftime Theactuatormoves a valve thereby allowing the amount of heat flowing to the heat...

Страница 2: ...inute B Confirm with OK D The motor will start moving back the control pin while the entries are still being made If InS is displayed with a rotating symbol this indicates that the motor is still moving back Once the device is ready for the actuator to be installed on the valve just InS will appear on the display Theweeklyprogramandothersettingscanbecustomisedpriortoinstallation Todothis pressthem...

Страница 3: ...00andfrom17 00until 23 00 respectively for every single day of the week from 00 00 to 06 00 17 0 C from 06 00 to 09 00 21 0 C from 09 00 to 17 00 17 0 C from 17 00 to 23 00 21 0 C from 23 00 to 23 59 17 0 C Torepresenttheswitchingperiods thedisplayshowsbarsforeveryotherswitchinginterval Inthisexample nobarsare shownfortheintervalfrom0 00to6 00 Barsareonlyshownonthedisplayfortheintervalsfrom6 00to9...

Страница 4: ...usingthe UnL Unlearn function Allwire less components are taught out at once with this function Press and hold down the menu button for more than 3 seconds Use the setting wheel to select the UnL menu item Confirm with OK ACC will appear on the display press OK to confirm Setting the holiday function Ifyouwantafixedtemperaturetobemaintainedforasetperiodoftimewhileyouareonholidayorduringaparty youc...

Страница 5: ...ion can be deactivated by selecting a time of 0 Setting the offset temperature Thetemperatureismeasuredattheheatingapplianceitself withtheresultthatotherpartsoftheroommaybewarmeror colderthanthis Toallowforthis youcansetatemperatureoffsetof 3 5 C If forexample atemperatureof18 Cismeasu red somewhere within the room instead of the 20 C set it means that an offset of 2 0 C needs to be configured Pre...

Страница 6: ...ves threaded connection M 28 x 1 5 1 6357 11 Thermostats Adapter Ring H threaded connection M 30 x 1 5 1 6351 01 Thermostats Adapter Ring for Caleffi Thermostatic Valves threaded connection M 30 x 1 5 1 6362 01 Thermostats Adapter Ring D threaded connection M 20 x 1 1 6362 11 Thermostats Adapter Ring for D threaded connection M 23 5 x 1 5 Radio remote control 1 8250 02 Buttons and display A Set te...

Страница 7: ...transmission symbol appears on the display The display switches off after 10 seconds of inactivity Ifthedisplayisstillactive changingthetemperatureagainwillcauseonlythenewtemperaturedifference17tobetransmit ted If the display has already switched off after 10 seconds of inactivity the temperature change starts again from 0 C 2 Comfort temperature Set back temperature The buttons are used to activa...

Страница 8: ...d on the frame the other on the window This ensures that when the window is opened the electronic unit registers that the magnet is no longer in the imme diate vicinity and a window open signal is transmitted Installation location First select the window that is frequently used for ventilation and which the window contact is to be attached to The magnet 1 can be installed on the left or right of t...

Страница 9: ...edofwithregulardomesticwaste Instead theyshouldbetakento your local battery disposal point Teaching in to radio components To enable radio components to communicate with one another they need to be taught in to one another The window contact can be taught in to system components such as a radio energy saving controller for radiators The first step is to switch the receiver to teach in mode For inf...

Страница 10: ...e components must first of all be set to teachin mode The USB programming stick must be plugged into the PC s USB port The PC software must be running on the PC and programming must be complete For transmission the receivermust be set to teach in mode For more information on this refer to the operating manual for the relevant device The USB programming stick can now send data to the devices that a...

Страница 11: ...ce under Human Interface Devices WiththeDeviceManageropenyoucanunplugtheUSBprogrammingstickandplugitbackin itshouldthenappearin the list of devices If an exclamation mark appears in front of the device you should update the Windows drivers For more information please refer to the corresponding Windows Help Technical characteristics Power supply USB connection Transmission frequency 868 3 MHz Open ...

Отзывы: