Outline of operation 

4.

Outline of operation 

4−1.

Normal operation 

 

Once this machine receives two kinds of codes, namely, ID1 and ID2, which were previously 

logged in, the contact output of either output 1 or output 2 runs during the preset time just as 

Receiving lamp 1 or Receiving lamp 2 lights on depending on the received code.   

When the code transmitted from Transmitter deployed can only correspond to the output 1, the 

output 2 becomes unused (when the input point number of Transmitter is 1-point). 

 

 

You can select the desired contact output time from among four types of 200ms, 400ms, 

600ms and 800ms.   

Setting is already established for this machine to prevent double counting in such a way that 

next signal cannot be received for 300ms after the last signal is received(unacceptable to 

change).  

 

 

4−2.

ID login 

 

Before using this machine, login the ID to decide the ID you need to receive.   

 

You can login two types of ID1 and ID2. Operation can run while only ID1 is logged in with ID2 

not being logged in. Besides, the same ID code for between ID1 and ID2 can be set, however, 

only the output for ID1 can run in this case.   

Also possible to clear the already logged in ID.   

 

 

Log in and clear the ID according to the following ways:     

To login the ID 

① 

Turn on the Power switch while pushing the Receiving lamp corresponding to the ID you 

need to log in. 

ID1

ID LOGIN SWITCH1   ID2

ID LOGIN SWITCH2 

(Receiving lamp can also be used as ID LOGIN SWITCH) 

② 

Verify that the ID LOGIN SWITCH corresponding to ID you need to login is blinking (at 

interval of 0.5sec). If it does not blink, try again.   

③ 

Within 30-second put the Transmitter of the ID you need to login into transmitting 

condition once.   

④ 

Within 5-second without a break put it into transmitting condition again.   

⑤ 

Once ID is logged in, blinking of ID LOGIN SWITCH turns into lighting.   

⑥ 

After login is finished, turn off the power once and then turn on the power again before 

use.  

 

Precautions during operation 

   

*Do not operate another Transmitter in the vicinity of Receiver during login operation.   

   

  It may cause an incorrect login.   

   

*Unless login operation is completed within the given time, the ID LOGIN SWITCH will light 

off. In such case, try again from the beginning.   

Содержание POKAYOKE TWF-600R

Страница 1: ...V20061020 POKAYOKE Receiver TWF 600R Operation Manual V 1 03 HERUTU ELECTRONICS CORPORATION 62 1 Toyooka Hamamatsu Shizuoka 433 8103 Japan TEL 81 53 438 3555 FAX 81 53 438 3411 ...

Страница 2: ......

Страница 3: ...orial symbols This pictorial symbol indicates a Reminder to attract an attention This pictorial symbol indicates a Prohibition to prohibit a certain action For the usage to be commonly applied in all the models Avoid using in a place with a plenty of humidity or dust Otherwise absorbing a dust or water contents may cause machine trouble fire or electrical shock For handling this machine This is th...

Страница 4: ...ower cord A short circuit or heating may cause a fire or electrical shock Do not use the Power plug with dust being adhered A short circuit or heating may cause a fire or electrical shock Do not give a strong impact onto the AC adapter It may cause an accident or machine failure If you find out deformed AC adapter do not use it It may cause an accident or machine failure Do not charge this equipme...

Страница 5: ...OVE SCREWS NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL THE FOLLOWNG APPLIES ONLY IN THE U S A This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interface and 2 This device must accept any interface received including interface that may cause undesired operation ...

Страница 6: ...1 Outline 1 2 Specification 2 3 Each part name 4 4 Outline of operation 5 4 1 Normal operation 5 4 2 ID login 5 4 3 Setting the contact output time 6 5 Installation method 7 6 Dimensional drawing 8 7 Guarantee 9 ...

Страница 7: ... can be received In addition to 65536 types the type of ID code can be further increased by adding the exclusive code The codes within the received frame data are compared with the code that was previously logged in this machine and only when they are consistent each other the output MOS FET relay goes into effect Due to the preset chattering prevention time it takes 300ms to reach receivable cond...

Страница 8: ... Noise permissible zone DCin 250V Machine dimension 120W x 168H x 38D mm Raised portion excluded Steel case material Steel plate SECC t 1 0 Painted and printed Interface MOS FET Relay x 4 point each point independently insulated Rated load voltage AC DC30V Rated load current 0 5A per point Connection method Screw terminal M3 5 8 piece Power switch Locker type Alternate 2 position 1 piece Switch ID...

Страница 9: ...onal communication system Electric wave type F1D Modulation method Binary FSK Modulation rate 1000bps Receiver frequency 426 1 MHz Receiving circuit system Double super heterodyne system Receiving sensitivity 0dBμVemf or less Antenna terminal BNC J Connector Nominal impedance 50Ω ...

Страница 10: ...tached antenna is connected by this part Nameplate label affix point The Model Serial No FCC ID IC CODE and Precautions in usage and etc are described DC Jack for feeding operating power DC Jack for feeding the operating power 12V Appropriate plug internal diameter φ 2 1mm External diameter φ 5 5mm Center minus Power switch BNC J Connector Nominal impedance 50Ω Antenna Antenna connected by BNC Con...

Страница 11: ...logged in Besides the same ID code for between ID1 and ID2 can be set however only the output for ID1 can run in this case Also possible to clear the already logged in ID Log in and clear the ID according to the following ways To login the ID Turn on the Power switch while pushing the Receiving lamp corresponding to the ID you need to log in ID1 ID LOGIN SWITCH1 ID2 ID LOGIN SWITCH2 Receiving lamp...

Страница 12: ... your hand from ID LOGIN SWITCH The blinking conditions of Receiving lamp indicate the current output time set values ID1 ID2 Contact output time lights off lights off 0 2sec lights on lights off 0 4sec lights off lights on 0 6sec lights on lights on 0 8sec To change the setting manipulate the ID LOGIN SWITCH within 5 seconds Once ID LOGIN SWITCH is pressed the lights on lights off will reverse Ma...

Страница 13: ...V with less variation Make a wiring for the output terminal block Output turns on with relay contact Once output turns on short circuited condition is made between terminals Once the rated contact load is exceeded inner circuit might be damaged Use an extreme care Rated load voltage AC DC30V per point Rated load current 0 5A per point Connection method Screw terminal M3 5 8 piece Internal Circuit ...

Страница 14: ...8 Dimensional drawing 6 Dimensional drawing ...

Страница 15: ...ter an antenna a connection cable except the main body do not include it 6 In the case of the trouble that occurred by the handling against usage mentioned in this instruction manual and instructions The guarantee certificate is attached on this product Confirm the prescribed contents and carefully keep it The guarantee period is one year The guarantee certificate is not attached on this product W...

Страница 16: ...bject to change without prior notice We take all possible measures for the contents stated in this manual however if it contains doubtful points contact our sales office We shall not be responsible for any influences resulting from use of this machine regardless of aforementioned provisions The product specification and appearance are subject to change for further improvement without prior notice ...

Отзывы: