ENGLISH
The Herschel PULSAR must be located in a position to
allow proper and efficient use but one that ensures
hot parts are not touched accidentally. The
recommended installation height of the White 1800W
Pulsar is 2.3m – 2.5m (90” – 110”) from the floor.
The recommended installation height of the Black
2400W Pulsar is 2.5 - 2.8m (98” - 110”) from the floor.
Under no circumstances is either unit to be installed at
less than 1.8m (71”) from the floor. In all cases it should
be installed at a height where it cannot be touched in
operation.
Consideration should be given to any temporary or
occasional additions such as stages or platforms, and
the height should be adjusted accordingly.
The Herschel PULSAR should be firmly and
permanently attached to a solid surface with a
minimum clearance of 0.60m (23.6”) between the top
surface of the heater and the ceiling.
Fixing must be effected by a mounting plate and
support chain or wire capable of carrying up to 112kg
(equal to 4x the weight of the Pulsar).
EXTERIOR USE:
The PULSAR is not approved for exterior use.
INITIAL USE:
There may be an odour or vapour from the heater on initial use or if heater has not been used for an
extended period. This is normal and is a result of a build up of dust.
USER MAINTENANCE:
The PULSAR is maintenance free but to maintain appearance it should occasionally be cleaned all over with
a soft dry cloth. No abrasive cloths or cleaners should be used and appliances such as pressure washers,
steam cleaners, etc, should never be used. Cleaning should only be done when the unit is cold and switched
off. All personnel cleaning and maintaining the unit must have suitable training and information to carry out
the operation safely.