5.

 

SET UP AND MANAGE ZONES 

WH1 has up to 6 zones and 6 R1’s within each zone. 

Use zones to group heaters by the way you wish to control 

them. For  example,  you may wish to put  several or all bedrooms onto one zone, hallways / bathrooms into 
another and living areas in another zone. Correctly set up zones will maximise efficiency and improve comfort 
levels.  For example, if you were having a party and wished to keep the heating on for longer than normal or 

increase the temperature, the use of a “living areas” zone would allow y

ou to do this easily without affecting 

the heaters in the other zones. 

If the number of R1’s within a zone exceed 6, a new zone will nee

d to be set up. 

5.1 TO SET UP ZONES 

From the Quick Actions screen, click 

to  access  the  Manage 

Zones page. 

 

 

 

Click the Zone you want to manage (long press). 

 

 

 

 

From this screen you will see overall zone status. Each R1 will show its own 
status which could be one of the following:  

 

 

 

R1 is greyed-

out.  This means the R1 hasn’t been paired.

 

 

R1  shows  a  white  icon  but  no  status  information.  This  means  the  R1  is  paired  but  has  lost 
communication. 

See “

Where should I locate my R1?

” and “What if an R1 i

s off-

line?” in the 

Frequently 

Asked Questions section for possible causes. 

The heater is operating normally on the chosen mode (schedule mode shown here) and is reporting 
the actual temperature. In their respective modes, the Comfort and Away symbol will appear. 

 

The red alert triangle signifies a “Window open” even

t has occurred with this R1. The Window Open 

function is described in Frequently Asked Questions.  

 
The R1 is Off. Note it is still receiving temperature information.  

 

Содержание iQ WH1

Страница 1: ...tive 2014 53 EU RED Directive 2009 125 EC Ecodesign Directive 93 68 EC CE Marking Directive Original instructions covering WH1 units produced 122017 onwards WH1 Central Control Unit Installation and O...

Страница 2: ...guidance provided in the current editions of BS7671 IEE Wiring Regulations 2 DO NOT install and run this system if local voltage exceeds 240 volts 3 Always isolate the AC mains supply before opening...

Страница 3: ...1 day scheduling with 4 programmes per day and Comfort and Away modes to give that extra boost when you want it and turn everything down when you don t HOW DOES IT WORK When installed the WH1 unit is...

Страница 4: ...lectrical equipment such as radios TV Wifi routers PCs etc Avoid placing in an area where young children could access the unit The WH1 requires a mains supply and must be mounted onto a recessed cable...

Страница 5: ...ring can only be carried out once the R1 units are installed and the power supply is on From the Quick Actions screen click the house icon in the bottom right to go to the Manage Zones screen below Se...

Страница 6: ...ndividual R1 icons will also show the mode that has been set This saves having to go into each zone to select the desired mode Override the overall setpoint temperature of every R1 Receiver in every z...

Страница 7: ...e Quick Actions screen click to access the Manage Zones page Click the Zone you want to manage long press From this screen you will see overall zone status Each R1 will show its own status which could...

Страница 8: ...er This takes you to a Quick Actions page similar to the home page just for managing this zone All actions you take apply just to this zone You can Turn the zone on or off Set Comfort Away or Schedule...

Страница 9: ...e Comfort and Away settings but in Schedule Mode remains active only until the next programme cycle You can set the MODE Comfort Away Schedule of the R1 Receiver You can SETUP the Comfort Away Schedul...

Страница 10: ...want to alter and click the settings icon This takes you to the Edit My Schedule page You can now set the characteristics of the 4 day programmes Select which programme using the up and down arrows l...

Страница 11: ...call for heat even if has been switched off by a WH1 function R1 cannot activate if switched off at the mains WARRANTY Register your product here https www herschel infrared com customer service warr...

Страница 12: ...ion large metal surface microwave oven proximity to Wifi Router The R1 may also just be at the limits of effective communication range walls metal obstacles like immersion heaters When an R1 is brough...

Страница 13: ...g Click to exit and you will notice the R1 is now grey How do I perform a factory reset Long press the Herschel icon on the home Quick Actions page Click the following the Reset instructions What if m...

Отзывы: