Locate lift on a level surface in a position most convenient for the loading and unloading of vehicles.
Obtain hose clamps
ID
Part #
Description
Qty.
1
720-122
CLAMP HOSE # 4 SS/Z
1
2
1001942
CLAMP HOSE CRIMP TYPE 1" Z
1
Using the 1" hose clamp (1001942), clamp the 5/8" ID air line (1001274) from the lift to 5/8" hose barb (1001393) on the
foot control assembly (see fig.1).
Using the #4 hose clamp (720-122), clamp the 1/4" ID air line (720-106) from the lift to hose barb (990) on the foot
control assembly (see fig.1).
NOTE: Check these connections periodically to prevent leakage.
Obtain 1/2 NPT connector compatible with the quick disconnect on your shop air line.
NOTE: Connector not supplied with lift.
Install 1/2 NPT connector into open port (Port 1) on the foot control valve (see fig.2).
Connect your shop air line to connector and test for proper operation.