S
AFETY
I
NSPECTION
31
12.1
Regular safety check
(In accordance with §10 ( 2 ) German Health and Safety regulations !)
Device type
Serial number
Inspection result
Start-up not permitted, verification required
Start-up possible, faults to be rectified by: ...............................................
No fault, start-up possible immediately
Safety inspection performed on:
……………………………………................................................
Name and address of qualified personnel
............................................................................................
…………………………………………
………………………………………..
Signature of competent person
Signature of operator
With the required rectification of faults
…………………………………………
………………………………………..
Signature of competent person
Signature of operator
Inspection step
O
K
N
o
t
O
K
re
-
e
x
a
m
in
a
ti
o
n
Remark
Nameplate
Sign with lifting capacity
Sign with bar mains pressure
Operating instructions (abbreviated)
Designation lift - lower
Secure fit of all supporting screws
Safeguard of the scissor pins
condition of the pneumatic lines
safety valve set to 3.5 bar operating pressure
Pressure gauge bar mains pressure P
max
= 8 bar
Control lever returns automatically to the '0' position when
released
Safety catch function
Loading ramps function
Condition of the air bags
Roll-off protection function
Condition of the supporting structure
Functionality of the service lift with vehicle
Functionality bogie