Pag.17
No ACTION
Possible problem/cause
Solution
3.
NO
Ignition components not operating
properly.
Check connection between cable & IGN
electrode.
Check IGN electrode spark gap.
Check IGN electrode for discharge to
ground (break in ceramic).
Check IGN cable for damage
Continuous spark
Increase distance between IGN cable and
all metal parts. Check that spark does
not discharge to ground at location of
spark plug connection. Shorten cable if
possible. If applicable, provide extra
insulation with silicon hose etc.
Spark will occur each
second.
NO
IGN sequence stops, no pilot flame.
No reaction to transmitter command
(receiver does not react).
Press RESET button, see instructions.
Add ground wire between pilot burner
and gas valve.
Do not coil the IGN cable.
Shorten IGN cable if possible.
NO
IGN sequence stops, no pilot flame.
Transmitter command is possible.
IGN sequence stops, no pilot flame.
Transmitter command is possible.
OK
4.
Pilot lit.
NO
TC and SW cable reversed.
Check connection of cable to receiver
and interrupter, see fig. 1.
Impulse magnet not operating properly. Replace gas valve.
Short between interrupter and SW
cable.
Check connection to interrupter.
OK
No gas magnet unit drops after 30
second audible count).
Check gas supply to gas valve.
5.
Sparking stops after
pilot is lit
NO
Short between interrupter and TC cable. Check connection to interrupter,
see fig. 1
OK
Electronic measuring amplifier defective. Replace receiver.
Interrupter
Receiver