background image

Pag.17 

No  ACTION 

 

  Possible problem/cause

 

 

Solution

 

 

 

 

 

   

 

3. 

 

NO 

  Ignition components not operating 

properly.  

Check connection between cable & IGN 

electrode. 

 

 

 

   

Check IGN electrode spark gap.  

 

 

 

   

Check IGN electrode for discharge to 

ground (break in ceramic).  

 

 

 

   

Check IGN cable for damage  

 

Continuous spark 

 

   

Increase distance between IGN cable and 

all metal parts. Check that spark does 
not discharge to ground at location of 
spark plug connection. Shorten cable if 

possible. If applicable, provide extra 
insulation with silicon hose etc.  

 

Spark will occur each 

second. 

 

   

 

 

 

NO 

  IGN sequence stops, no pilot flame. 

No reaction to transmitter command 
(receiver does not react).  

Press RESET button, see instructions.  

 

 

 

   

Add ground wire between pilot burner 

and gas valve.  

 

 

 

   

Do not coil the IGN cable. 

 

 

 

   

Shorten IGN cable if possible. 

 

 

 

   

 

 

 

NO 

  IGN sequence stops, no pilot flame.  

Transmitter command is possible.  

IGN sequence stops, no pilot flame.  

Transmitter command is possible.  

 

              OK 

 

   

 

4. 

Pilot lit.  

NO 

 

  TC and SW cable reversed. 

Check connection of cable to receiver 

and interrupter, see fig. 1.  

 

 

 

  Impulse magnet not operating properly.   Replace gas valve. 

 

 

 

  Short between interrupter and SW 

cable.  

Check connection to interrupter. 

 

              OK 

 

  No gas magnet unit drops after 30 

second audible count).  

Check gas supply to gas valve.  

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

5. 

Sparking stops after 

pilot is lit  

NO 

  Short between interrupter and TC cable.   Check connection to interrupter,  

see fig. 1  

 

              OK 

 

  Electronic measuring amplifier defective.  Replace receiver.  

Interrupter

 

 

Receiver

 

 

Содержание Harmony 25

Страница 1: ...Pag 1 OPERATING AND INSTALLATION INSTRUCTION STANFORD HARMONY 25 STANFORD HARMONY 35 UNITED KINGDOM UK IRELAND IE...

Страница 2: ...as lines 3 2 Preparation and installation 3 3 Fitting the ceramic logs 4 TECHNICAL DETAILS GV60 Page 9 5 INSTRUCTIONS FOR MERTIK MAXITROL GV60 GASCONTROL Page 10 6 GAS TECHNICAL DATA Page 11 7 CONCENT...

Страница 3: ...fter the batteries have been inserted press the OFF button and small at the same time to toggle between F and 12 hour clock and C and 24 hour clock Wait a moment or press OFF to return to MAN mode 1 4...

Страница 4: ...ited the flame will adjust to its maximum height automatically 1 7 Possible error messages Long sound signals during ignition Receiver batteries are almost empty After this signal is heard the unit ma...

Страница 5: ...ly 1 10 Inserting and replacing the batteries The manual transmitter and receiver batteries have a life span of approximately one year The use of alkaline batteries is recommended The batteries need t...

Страница 6: ...able to see whether the pilot flame is burning through the glass window If the pilot flame is alight keep the metal circle pressed down for another 10 seconds and then let go Turn the operating butto...

Страница 7: ...d check whether the burner flame is uniform After the unit has been used for the first time you should remove any deposits resulting from Running burning in the paint using a glass cleaner for heaters...

Страница 8: ...over the burner and the burner decoration plate so that they are just covered Glowing embers can be placed here and there as decoration Place the ceramic wood blocks in the correct order as shown on A...

Страница 9: ...gory C11 C31 C91 Combustion gas discharge and Combustion air supply Concentric 100 150 mm 4 TECHNICAL DETAILS GV60 Main valve knob Thermocouple connection Pressure regulator Ignition connection Pilot...

Страница 10: ...control block should be turned to the ON position The I 0 switch should to be set to I The ignition must be connected to the receiver box at the terminal SPARK The transmitter s contains the thermosta...

Страница 11: ...MBAR 20 Mbar 20 25Mbar 30 30 37 30 Mbar BURNERPRESSURE HIGH MBAR 18 5 18 28 9 BURNERPRESSURE LOW MBAR 3 6 3 11 INJECTOR SIZE MM 1 9 2 1 1 15 INJ PILOTBURNER CODE 51 51 30 LOWSETTING SIZE MM 1 7 1 7 1...

Страница 12: ...striction Baffle plate 0 3 meter no yes 3 7 meter 30 mm yes 7 12 meter 50 mm yes Vertical path with bends 45 X total Y 3 6 meter 30 mm yes 45 X total Y 6 12 meter 50 mm yes 90 X total Y 4 6 meter 30 m...

Страница 13: ...ue should be cased if necessary Sufficient fireproof measures must also be taken when the flue is being mounted along flammable materials Determine the position of the unit and outlet and begin constr...

Страница 14: ...is in place using 2 parkers Level the bottom side of the adjustable pipe 5 with the ceiling of existing chimney Shorten the flexible hose to approximately 100 mm above the existing chimney top Attach...

Страница 15: ...ow Floor ceiling support Fire stop plate flat Concentric element Wall bracket Floor support Fire stop plate flat Locking band 9 Roof terminal 8 Locking band 7 Chimney connection set Renovation kit 6 F...

Страница 16: ...receiver range limited 1 Move antenna cable see instructions 2 Replace receiver Optional wall switch cabling not operating properly Replace wall switch cabling Receiver fuse blown in older versions on...

Страница 17: ...es not react Press RESET button see instructions Add ground wire between pilot burner and gas valve Do not coil the IGN cable Shorten IGN cable if possible NO IGN sequence stops no pilot flame Transmi...

Страница 18: ...ver does not react Press RESET button see instructions Add ground wire between pilot burner and gas valve OK Do not coil the IGN cable Shorten IGN cable if possible 7 Main burner is lit NO Gas valve m...

Страница 19: ...instructions The main burner goes out when the unit is warm 1 This can be a normal effect of the thermostat Check whether the pilot flame is able to heat the thermocouple adequately If the pilot flam...

Страница 20: ...Pag 20 APPENDIX 1 DIMENSIONAL DRAWINGS Stanford Harmony 25 TOP CONNECTION Stanford Harmony 35 TOP CONNECTION...

Страница 21: ...s A combustible shelf may be fitted over the appliance if in the case of a 150mm or less deep shelf there is at least 280mm clearance above the top of the stove The shelf depth may increase at the sam...

Страница 22: ...Pag 22 APPENDIX 3 FITTING LOG SET Stanford Harmony 25 NG LPG...

Страница 23: ...Pag 23 Stanford Harmony 35 NG...

Страница 24: ...24 Industrias Herg m S A Soto de la Marina Cantabria Espa a Stanford Harmony 35 LPG Place behind the horizontal log embers to break the high pointed flame Place embers under the open space Horizontal...

Отзывы: