WARNING: THE APPLIANCE & FLUE SYSTEM SHALL BE INSTALLED IN ACCORDANCE 

WITH AS/NZS 2918:2018 AND THE APPROPRIATE REQUIREMENTS OF THE RELEVANT 

BUILDING CODE OR CODES. 

 

WARNING: APPLIANCES INSTALLED IN ACCORDANCE WITH THIS STANDARD SHALL 

COMPLY WITH THE REQUIREMENTS OF AS/NZS 4013:2014 WHERE REQUIRED BY THE 

REGULATORY AUTHORITY, I.E. THE APPLIANCE SHALL BE IDENTIFIABLE BY A 

COMPLIANCE PLATE WITH THE MARKING “TESTED TO AS/NZS 4013:2014”. 

 

ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING 

BY THE TESTING AUTHORITY IS CONSIDERED TO BE IN BREACH OF THE APPROVAL 

GRANTED FOR COMPLIANCE WITH AS/NZS 4013:2014.

 

 
CAUTION: MIXING OF APPLIANCE OR FLUE SYSTEM COMPONENTS FROM DIFFERENT 

SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION OF COMPONENETS MAY 

RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS CONSIDERED, THE 

MANUFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE. 

 
CAUTION: CRACKED AND BROKEN COMPONENTS, e.g. GLASS PANELS OR CERAMIC 

TILES, MAY RENDER THE INSTALLATION UNSAFE. 

 

1.  WARNING:  ANY MODIFICATION OF THE APPLICANCE THAT HAS NOT BEEN 

APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS 

BREACHING AS/NZS 4013. 

 

2.  WARNING:  DO NOT US FLAMMABLE LIQUIDS OR AEROSOLS TO START OR 

REKINDLE THE FIRE. 

 

3.  WARNING:  DO NOT US FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY 

OF THIS APPLICANCE WHEN IT IS OPERATING. 

 

4.  WARNING:  DO NOT STORE FUEL WITHIN THE HEATER INSTALLATION 

CLEARANCES. 

 

5.  WARNING:  WHEN OPERATING THIS APPLICANCE AS AN OPEN FIRE USE A FIRE 

SCREEN. 

 

6.  WARNING:  OPEN AIR CONTROL (AND DAMPER WHEN FITTED) BEFORE 

OPENING FIRING DOOR. 

 

7. 

CAUTION:  THIS APPLIANCE SHOULD NOT BE OPERATED WITH A CRACKED 

GLASS. 

 

8. 

CAUTION:  THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL 

TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS. 

 

9. 

CAUTION:  THE USE OF SOME TYPES OF PRESERVATIVE-TREATED WOOD AS A 

FUEL CAN BE HAZARDOUS.

 

 

Содержание Glance L

Страница 1: ...ual INSTALLATION USE AND MAINTENANCE INSTRUCTIONS Certified to AS NZS 4012 2014 AS NZS 4013 2014 Please read this manual thoroughly before installing and starting your fireplace Keep These Instruction...

Страница 2: ...caused by alterations to its products that have not been authorized in writing or for defective installation work Due to continuous improvement Hergom reserves the right to change its products withou...

Страница 3: ...resentation 5 INSTALLATION INSTRUCTIONS 3 Dimensions 6 4 Safety Clearances and Flue Install 8 5 Heatshield installation for Rear clearance 11 6 Installation instructions for Upper Baffle Draft Reducer...

Страница 4: ...N IS CONSIDERED THE MANUFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE CAUTION CRACKED AND BROKEN COMPONENTS e g GLASS PANELS OR CERAMIC TILES MAY RENDER THE INSTALLATION UNSAFE 1 WARNING ANY MODI...

Страница 5: ...o made of vermiculite with a stainless steel vertical top baffle extension The tertiary burn of flue products above the baffle also making the unit more efficient The chimney flue can exit through the...

Страница 6: ...ed in uneven surfaces This fireplace provides heat by radiation directly heating walls ceilings furniture and you Fully factory assembled ready for connection to the chimney flue 3 DIMENSIONS GLANCE L...

Страница 7: ...corative 8 200mm SAFETY DISTANCES Dimensions per Fig 4 and 5 below All Dimensions in mm A B C D E F G H I J K No Firebox Shield 560 750 400 400 1260 970 450 510 150 1422 1200 Firebox rear heat shield...

Страница 8: ...blocked Ensure that the pipe connecting the stove to the outside cannot be crushed and that the entrance to the pipe cannot be blocked on the outside It is necessary to cover the inlet with a protect...

Страница 9: ...reduced rear clearances it requires a deflector shield between the 6 Active and the 8 solid heat shield for the first length of flue The heater must have its own dedicated flue The active flue must be...

Страница 10: ...10 External Requirements Refer to AS NZS 2918 2018 Note All external air vents ceiling penetrations must be bird rodent proofed with permanently fixed screens...

Страница 11: ...involves several factors and it takes time and experience to understand the process Before lighting your stove for the first time please take time to become familiar with the different control systems...

Страница 12: ...3 Ash pan Very important Only handle the ash pan when the stove is cold Always avoid opening the ash pan if your stove is in operation To clean the ash lift the solid base plate located at the bottom...

Страница 13: ...bustion chamber The heater must be closed at all times during combustion to prevent smoke from leaking out Only open the door to add fuel Daily use After lighting up for the first time your heater wil...

Страница 14: ...emove the ash pan and remove the ash Ash should be emptied into a metal container and immediately removed from the house If necessary clean the ash pan housing Enameled parts Applies only to certain m...

Страница 15: ...When installing the stove observe the necessary safety distances for the oven and chimney from combustible surfaces wooden or papered walls wooden floors Safety distances must be respected when the li...

Страница 16: ...50 Outside air inlet pipe diameter mm 80 Minimum diameter of the outside air inlet pipe mm 80 Maximum length of the outside air inlet pipe from outside m 8m In the case of other dimensions consult you...

Страница 17: ...17 12 EXPLODED PARTS VIEW Part number on Drawing referenced in Table below for ordering purposes Note 6 different drawings total...

Страница 18: ...18...

Страница 19: ...19 B DOOR C SIDE PANELS D LEGS E TOP PANELS F REAR SHIELD...

Страница 20: ...20 13 SPARE PARTS LIST We recommend only using spare parts recommended by the manufacturer...

Страница 21: ...tions Conditions to activate the warranty 1 The appliance must be within the time limits described above the date from which the product was purchased will be considered as the start of the warranty p...

Страница 22: ...DANCE WITH AS NZS4012 2014 AS NZS4013 2014 MAXIMUM AVERAGE HEAT OUTPUT BURNING HARDWOOD 6 6kW OVERALL AVERAGE EFFICIENCY BURNING HARDWOOD 60 PARTICULATE EMISSIONS FACTOR 1 2g kg TEST REPORT NO ASFT180...

Отзывы: