background image

COMBUSTION PHASES IN A CONTINU-

 

            OUS FIRE SITUATION

 

You should not continuously supply firewood to the

 

fireplace because in this way you interrupt combustion

 

transformation phases and performance decreases.

 

First phase: loss of humidity and combustion of

 

gas substances.

 

Second phase: transformation of firewood into coal,

 

increase of heating value and weight loss.

 

Third phase: maximum combustion performance.

 

Fourth phase: slow combustion and progressive power

 

decrease.

 

Clean firewood combustion is a process similar to na-

 

tural decomposition, which means that the CO2 (car-

 

bon dioxide) being freed does not increase or alter

 

the original concentration of CO2 in the atmosphere.

 

Chimney

 

The chimney will be rainproof.

 

The thermal resistance of chimney walls should be

 

at least 0.43 m2kw.

 

The chimney must extend 1.20 m over the ridge of

 

the roof.

 

Thermal insulation of the duct

 

The passage of the duct through a wall of an inhab-

 

ited room shall be isolated with fireproof material in

 

order to avoid fire; the minimum distance between the

 

duct and all combustible elements (beams, wooden

 

floors, etc.) will exceed 16 cm.

 

AIR INLET

 

− It should be placed directly outside or inside a ven-

 

tilated room, with the right dimension and with the

 

protection of a grid.

 

− Insulation of the breast wall: insulation is fundamen-

 

tal for light structures, and it is also recommended to

 

avoid loss of heat, thus achieving better thermal ef-

 

ficiency.

 

− Lifting of the compact fireplace: it is possible up to

 

the height indicated in the design using, for example,

 

Gasbeton ® blocks with the suitable shape.

 

− Place the marble/stone covering: with the right

 

shape according to the design. Provide a stable sup-

 

port at least on three points or, if it is overhanging,

 

provide suitable hidden metal supports. The width of

 

the marble/stone top in front of the fireplace should

 

be more than 30 cm if the floor is made of wood, fit-

 

ted carpet or any other inflammable material.

 

− If there is a wooden lintel, it should be protected.

 

− It is compulsory to build the hood with insulating

 

and fireproof materials. The hood is generally made

 

of plasterboard; to avoid overheating it is necessary

 

to create a ventilation system in the hood through

 

grids, placed in the correct places, to allow the air

 

to circulate; grids, however, have to be placed at the

 

highest point, but never less than 30 cm from the ceil-

 

ing with grids with a surface of 600 cm2.

 

Optimum usage

 

Do not force the fireplace when used for the first

 

times; during the first few days use the equipment at

 

50% in order for its components to expand and set-

 

tle evenly. Always use dry firewood with a maximum

 

humidity of 15%; always charge ¾ big pieces sepa-

 

rated in time, avoid continuously opening the door

 

to add small pieces of wood because this increases

 

firewood consumption; control combustion by means

 

of the primary air inlet.

 

Notes on fuels

 

Allowed: firewood, lignite, compressed logs.

 

Do not burn: cardboard, wooden pallets, plastic, al-

 

cohol, gas oil or other flammable liquids.

 

FLUE

 

The existing duct or the one to be built must comply

 

with the existing regulations.

 

Existing duct

 

Make sure that it is well sealed.

 

Make sure that it is not connected to another fire-

 

place.

 

Make sure that the chimneypot is in good conditions

 

and that the height and diameter are correct.

 

Building of a metal duct

 

The material to be used is AISI 316 double-walled

 

stainless steel, with a 4/10 minimum thickness (the

 

best value would be 1 mm), installed according to the

 

rules of the manufacturer.

 

Building a refractory material duct

 

This duct is built with three concentric layers, each one

 

with a specific function:

 

− The first layer of refractory material guarantees the

 

waterproof nature of the product, air-tightness and re-

 

sistance to corrosion and heat.

 

− The second intermediate layer, apart from the in-

 

sulating function, provides for longitudinal and trans-

 

verse expansion of the refractory material with re-

 

spect to the external wall.

 

− The third external layer performs insulating, protect-

 

ing, guiding and containing functions typical of refrac-

 

tory material.

 

This kind of flue is the optimal solution in terms of func-

 

tionality and endurance in time.

 

31

 

Содержание ECK

Страница 1: ...SO E LA MANUTENZIONE INSTRUCCIONES PARA INSTALACI N USO Y MANTENIMIENTO INSTALLATION USE AND MAINTENANCE INSTRUCTIONS INSTRUCTIONS D INSTALLATION DE SERVICE ET D ENTRETIEN INSTRUC ES PARA A INSTALA O...

Страница 2: ...et fuel or an excessively low gas opera tion may lead to inflammable materials building up in the flue e g soot and tar that after a certain time may lead to the risk of fire In this case close all ai...

Страница 3: ...e disposal installation Combustion of waste and unsuitable material such as plastic treated wood etc leads to poor combustion and cancellation of the warranty Further consequences include damaging and...

Страница 4: ...protected It is compulsory to build the hood with insulating and fireproof materials The hood is generally made of plasterboard to avoid overheating it is necessary to create a ventilation system in...

Страница 5: ...or a faster combustion if com pared to bigger pieces In the compact fireplaces with ventilation the switch has to be adjusted according to different needs Combustion residues includefirewood mineral e...

Страница 6: ...re usually uniformly dry Inappropriate fuel Or with the use of lignite blocks the glass gets dirty faster than with firewood Refer to the Short information on materials and ways of combustion section...

Страница 7: ...2 year warranty on the Diva compact fireplace You will have to provide the registration number of the compact fireplace in the event of neces sary interventions covered by the warranty The warranty do...

Страница 8: ...s wait until it has completely cooled down To open the door horizontally pull up the horizontal opening handle FIG 1 Perform the glass cleaning process using a suitable detergent Cleaning of painted s...

Страница 9: ...place your ECK must be flat and provide a perfect seat for your fireplace The base must be built using heat resistant materials b The space where the ECK is to be inserted must be free of rubble and...

Страница 10: ..._S FD5001_1030MM FD5001_1030MM FD5001_1000MM ECKP002B ECKSP001 ECKP001S FD5001_3000MM ECKSP002 ECKP005A_S ECKP005B_S ISO_7380 M5X10 ECKP004 FD5001_455MM FD5001_455MM ECKP003 ECKP009 42456120 FD5001_46...

Страница 11: ...TZN7380510 0553Z6008_003 0553Z6009_002 T9345 0553Z6001S_002 Q00087 TZN7380510 TZN7380516 FIG 2 38...

Страница 12: ...615 240 323 508 1315 849 25 0 12 0 FIG 3 39 852 256 569 106 615 760...

Страница 13: ...FRACTORY ECK Mount bottom fig 1 Mount rear refractory fig 2 Mount right refractory side fig 3 Mount left refractory side fig 4 Mount baffle plate support fig 5 Mount baffle plate fig 6 Mount ash pan f...

Страница 14: ...ended minimum flue Primary air control Weight Height Width 13 kW 4 4 Kg 298 C 0 12 75 LEE 043 09 NB 1722 CEIS 400 mm 508 mm 760 360 mm 250 mm int 250 mm int da 5 a 6 m 250x250 mm verticale 12 Pa manua...

Страница 15: ...iva Recommends using the packaging wood and cardboard That comes with the device as fuel for the first times you light your Herg m product This is a way of contributing to the better use of resources...

Страница 16: ...INDUSTRIAS HERGOM S A SOTO DE LA MARINA CANTABRIA Apdo de correos 208 SANTANDER Tel 0034 942 587 000 E mail hergom hergom com www hergom com...

Отзывы: