background image

  Congratulations for choosing a new Diva

 

  compact fireplace. Following the advice

 

  and instructions of this manual will allow

 

you to enjoy your fireplace for a long time.

 

• DIVA heating devices are very high level products

 

of the greatest technical quality.

 

• This series of products has been especially con-

 

ceived with the reduction of gas values in mind, reduc-

 

ing at the same time fuel consumption and achieving

 

the highest performance levels.

 

• The great easiness of use and effective fuel con-

 

sumption make these fireplaces a good heating source

 

able to create, at the same time, a warm and homely

 

atmosphere.

 

• The original Diva fireplaces feature a nameplate

 

indicating: model, thermal capacity and Diva registra-

 

tion number.

 

• The owner or the authorized user must keep techni-

 

cal documentation at hand and show it to authorities

 

or chimneysweeps, if required to do so.

 

BEFORE INSTALLATION

 

Before installing a fireplace it is important to carry out

 

an inspection to decide where to place it and consider

 

the following aspects:

 

• Volume to heat-up in sq.m.

 

• Thermal insulation of the room

 

• Consider the roof, thermal insulation of the house,

 

double glazing, etc.

 

• Geographical position of the house, internal/exter-

 

nal temperature variation

 

• Check whether the flue (if it exists) is complete and

 

straight; points of contact between fumes and inflam-

 

mable material.

 

• The draft regulator is compulsory if the steel flue is

 

higher than five meters.

 

• It is compulsory to insulate the hood.

 

• External air inlet dimensioning

 

• It is advisable to use good firewood as fuel to get

 

the best out of the new fireplace.

 

• Floor capacity: please check whether the floor un-

 

der the fireplace is capable of supporting the weight.

 

• To connect the fume outlet pipe to the flue it is ad-

 

visable to call a specialized technician to avoid gas

 

leaks or fire hazards.

 

• In case of bad atmospheric conditions (thermal con-

 

version), it is very important to check smoke leakage,

 

combustion gas and draft conditions. In case of com-

 

bustion gas leaks, let the fire go out, check that all

 

air inlets are free and that the flue is clean and free

 

from obstacles. In case of any doubt, please call the

 

chimneysweep service, since a draft problem may be

 

related to the conditions of the flue.

 

• Before adding more fuel, please gather embers to

 

form an even layer.

 

• The use of wet fuel or an excessively low gas opera-

 

tion may lead to inflammable materials building-up in

 

the flue, e.g. soot and tar, that after a certain time

 

may lead to the risk of fire. In this case close all air

 

inlets and covers. Immediately call the fire brigade

 

and make sure all neighbours are safe.

 

• When adding fuel with high flames, avoid opening

 

the door too fast in order to prevent the flames com-

 

ing out.

 

Importance of the fuel

 

Firewood (oak, beech, ash-tree) is the recommend

 

fuel; it is also possible to use compressed wood logs

 

or lignite blocks. The use of waste fuels, rubbish or

 

plastic is forbidden. The use of resinous wood (fir-tree

 

and pine-tree) is not recommended, since it requires a

 

more frequent mechanical cleaning of the flue.

 

Dry wood with less than 20% humidity should be

 

used, since the combustion of wet wood could lead

 

to a soot build-up in the flue and negatively affect the

 

draft of the compact fireplace. Alternative fuels to fire-

 

wood: lignite blocks, compressed wood logs. Lignite

 

blocks produce a lot of ashes; therefore the fireplace

 

needs cleaning more frequently. Logs are very good,

 

but do not guarantee endurance. Use only dry ma-

 

terial. Burning waste of any kind (especially plastic)

 

damages the compact fireplace and the flue, and fur-

 

thermore it is prohibited by the law on toxic substance

 

emissions.

 

ASSEMBLY INSTRUCTIONS

 

General warnings and precautions

 

• Before assembling the Diva compact fireplace it is

 

important to be aware of regional construction laws;

 

the installer, chimneysweep or authorized Diva resel-

 

ler will be able to provide you with this information.

 

• Before using your compact fireplace, read this man-

 

ual carefully.

 

• When transporting your heating device, only use

 

means capable of supporting the load.

 

• When lighting the fire, please use only the heating

 

material indicated in the “Combustion and cleaning”

 

chapter

 

• It is totally forbidden to burn or put inflammable

 

or explosive substances in the combustion chamber,

 

e.g.: spray bottles and the like, fireworks and the like.

 

It is also forbidden to keep them near the fireplace.

 

These actions may lead to a risk of explosion.

 

• When adding fuel to the fireplace, do not wear

 

loose or inflammable clothes.

 

• It is forbidden to put non-heat-resistant objects on

 

the fireplace or near it.

 

• Drying racks or the like are to be kept at an accept-

 

able distance from the fireplace, to avoid the risk of

 

fire!

 

• When the fireplace is lit, do not handle inflammable

 

or explosive materials in the same room as the fire-

 

place or in nearby rooms.

 

29

 

Содержание ECK

Страница 1: ...SO E LA MANUTENZIONE INSTRUCCIONES PARA INSTALACI N USO Y MANTENIMIENTO INSTALLATION USE AND MAINTENANCE INSTRUCTIONS INSTRUCTIONS D INSTALLATION DE SERVICE ET D ENTRETIEN INSTRUC ES PARA A INSTALA O...

Страница 2: ...et fuel or an excessively low gas opera tion may lead to inflammable materials building up in the flue e g soot and tar that after a certain time may lead to the risk of fire In this case close all ai...

Страница 3: ...e disposal installation Combustion of waste and unsuitable material such as plastic treated wood etc leads to poor combustion and cancellation of the warranty Further consequences include damaging and...

Страница 4: ...protected It is compulsory to build the hood with insulating and fireproof materials The hood is generally made of plasterboard to avoid overheating it is necessary to create a ventilation system in...

Страница 5: ...or a faster combustion if com pared to bigger pieces In the compact fireplaces with ventilation the switch has to be adjusted according to different needs Combustion residues includefirewood mineral e...

Страница 6: ...re usually uniformly dry Inappropriate fuel Or with the use of lignite blocks the glass gets dirty faster than with firewood Refer to the Short information on materials and ways of combustion section...

Страница 7: ...2 year warranty on the Diva compact fireplace You will have to provide the registration number of the compact fireplace in the event of neces sary interventions covered by the warranty The warranty do...

Страница 8: ...s wait until it has completely cooled down To open the door horizontally pull up the horizontal opening handle FIG 1 Perform the glass cleaning process using a suitable detergent Cleaning of painted s...

Страница 9: ...place your ECK must be flat and provide a perfect seat for your fireplace The base must be built using heat resistant materials b The space where the ECK is to be inserted must be free of rubble and...

Страница 10: ..._S FD5001_1030MM FD5001_1030MM FD5001_1000MM ECKP002B ECKSP001 ECKP001S FD5001_3000MM ECKSP002 ECKP005A_S ECKP005B_S ISO_7380 M5X10 ECKP004 FD5001_455MM FD5001_455MM ECKP003 ECKP009 42456120 FD5001_46...

Страница 11: ...TZN7380510 0553Z6008_003 0553Z6009_002 T9345 0553Z6001S_002 Q00087 TZN7380510 TZN7380516 FIG 2 38...

Страница 12: ...615 240 323 508 1315 849 25 0 12 0 FIG 3 39 852 256 569 106 615 760...

Страница 13: ...FRACTORY ECK Mount bottom fig 1 Mount rear refractory fig 2 Mount right refractory side fig 3 Mount left refractory side fig 4 Mount baffle plate support fig 5 Mount baffle plate fig 6 Mount ash pan f...

Страница 14: ...ended minimum flue Primary air control Weight Height Width 13 kW 4 4 Kg 298 C 0 12 75 LEE 043 09 NB 1722 CEIS 400 mm 508 mm 760 360 mm 250 mm int 250 mm int da 5 a 6 m 250x250 mm verticale 12 Pa manua...

Страница 15: ...iva Recommends using the packaging wood and cardboard That comes with the device as fuel for the first times you light your Herg m product This is a way of contributing to the better use of resources...

Страница 16: ...INDUSTRIAS HERGOM S A SOTO DE LA MARINA CANTABRIA Apdo de correos 208 SANTANDER Tel 0034 942 587 000 E mail hergom hergom com www hergom com...

Отзывы: