User manual Integra Mini 300
22
HENSEL-VISIT International GmbH
Replacement of modeling light
The halogen lamp for the compact flash unit’s modeling light is
plug-in style. In case of a defect, the lamp can be replaced by
the operator.
ATTENTION!
Turn the unit off and disconnect it from any power supply before
replacing the modeling light. Wait at least 15 minutes before
continuing the procedure and until the halogen lamp has cooled
off.
Avoid handling the lamp with your bare hands to prevent con-
taminating the glass of the lamp with the oil of your skin. This
would reduce the operational life of the lamp. Please use cotton
gloves.
Â
Remove the protective glass cover; see „Protective glass
cover“ on page 11
Â
Carefully remove the lamp from the plug socket
Â
Insert a new lamp of the correct type
Please make sure the lamp is properly secured when replacing
the modeling light; see „Replacing the fuses“ on page 19 .
Maximum modeling lights to be used are:
300W/G6.35/115V or 300W/G6.35/230V
The modeling light to be inserted has to match the power volta-
ge.
Error messages
In case of an error, an error code is displayed in Display
3
. In
such an event, follow these steps:
Â
Turn the unit off
Â
Wait a few seconds
Â
Turn the unit on again
Should the error code persist, use the following checklist to see
if the malfunction can be corrected or contact a customer ser-
vice point; see „10 Customer service points“ on page 25.
Содержание Integra Mini 300
Страница 1: ...Integra Mini 300 Kompaktblitzgerät Compact flash ...
Страница 31: ......