background image

User manual Integra Mini 300

18

HENSEL-VISIT International GmbH

Daily flash count

The number of flashes which were triggered since last resetting 

the counter is displayed on LED-display 

3

.

This is how you read the daily flash count:

 

Â

Hold down the touch key 

SLAVE 14

 for one second.

The LED 

11

 is blinking and Display 

3

 shows the number of 

flashes.

The range of the counter is up to 9999.  The double-digit LED 

display 

3

 indicates the number in two steps. The numbers from 

00 to 99 are shown in the first setting.  The two additional digits 

are shown when pressing the key 

p 

5

.  The touch keys 

p 

5

 

and

  

q 

4

 allow you to cycle through the double digit settings.

Example:

2. Setting  

1. Setting 

Total

00 

 

22 

 

22 flashes

21 

 

47 

 

2147 flashes

01 

 

01 

 

101 flashes

This is how you re-set the daily flash count:

 

Â

While in flash count mode, hold down the touch key 

LAMP 13

The display 

3

 is reset to 00.

Содержание Integra Mini 300

Страница 1: ...Integra Mini 300 Kompaktblitzgerät Compact flash ...

Страница 2: ...OFF ON 115 230 V 50 60 Hz FUSE 4AF Made in Germany SLAVE TEST LAMP 16 15 14 13 12 11 10 9 17 18 19 20 21 22 1 2 3 4 5 6 7 8 ...

Страница 3: ...document and the use and transfer of its content is not permitted unless such right is explicitly granted In case of violation payment of compensati on will be due All rights reserved in case of patent approval or registration of utility model DIN 34 1 Printing errors excepted and subject to modifications of tech nical data The listed data are standard values and are not to be misconstrued as guar...

Страница 4: ... information do you keep the warranty effective prevent damages and extend the useful life of this product The company Hensel Visit took great care and observed all pertinent regulations in order to manufacture a safe product of highest quality Stringent quality management procedures ensure our high quality level also regarding our large scale production series Please add your part and handle this...

Страница 5: ...mary of control elements 10 7 Initial use 11 Acclimatization 11 Removal of transport cap 11 Protective glass cover 11 Insert flash tube 12 Inserting halogen lamp for modeling light 12 Set up 13 Power supply 13 8 Operation 15 Switch on off 15 Modeling light 15 Performance output adjustment 16 Test flash 16 Flash ready 16 Synchronization 16 9 Maintenance 19 Regular maintenance intervals 19 ...

Страница 6: ...fuses 19 Replacement of flash tube 20 Replacement of modeling light 22 Error messages 22 Warranty 24 Disposal 24 10 Customer service points 25 Manufacturer s service 25 Service points listed in the Internet 25 11 Accessories 26 12 Subject index 27 13 Declaration of Conformity 28 ...

Страница 7: ...ved accessories listed in this manual The unit is not to be used for applications other than those de scribed herein especially not for other electrical applications Set up and initial use Do not use the flash unit in environments that include explo sion hazards Make sure that the power supply corresponds with the infor mation on the labelling Compact flash units and generators must only be connec...

Страница 8: ...e any objects coffee cups containers filled with liquids etc on top of the device Protect the device from moisture dripping or splashing water Choose safe locations for placement of the device and make sure that it cannot fall into pools or bodies of water Keep sufficient safety distance from flammable materials like decorations papers etc to prevent a possible fire Secure the unit with a back up ...

Страница 9: ...ged This means touching the device could pose a life threatening danger Halogen lamps and flash tubes can burst which is why they must only be used with properly mounted safety cover ATTENTION Contact with capacitor voltage can pose a mortal danger Repairs or opening the housing must only be done by an autho rized customer service provider Working with the device Do not flash directly into someone...

Страница 10: ...are built in to a sturdy metal housing Scope of delivery Please check the scope of delivery before initial use Note The scope of delivery may vary depending on order configurati on and country of delivery Please see corresponding informati on on your delivery documents and order forms Standard scope of delivery includes Flash tube single coated plug in type Modeling light enclosed Tilting bracket ...

Страница 11: ...w 300W G6 35 230V Modeling light adjustment OFF proportional AUTORED Sync plug voltage 6 3 jack plug Mono 5 VDC Fuses F 4 A H Power supply Multivoltage 110 230 V Weight approx 2 3 kg Dimensions in cm only casing LxWxH 23x12 3x14 Dimensions in cm overall LxWxH 26x12 3x18 Additional features Thermal check of performance electronics Daily flash counter reset function yes Integrated ventilator yes Pho...

Страница 12: ...le bar 7 Locking mechanism reflector holder 8 Sync plug 9 Photo cell 10 Display flash ready 11 Display Slave photo cell 12 Display modeling light 13 Modeling light 14 Slave photo cell on off 15 Test trigger flash 16 Fuse and spares 17 Locking mechanism umbrella holder 18 Compartment for spare fuses 19 Locking mechanism for stand 20 Safety screw for suspended mounting 21 Locking mechanism tilting b...

Страница 13: ...reflector  ÂPush the locking mechanism of the reflector holder 7 against the spring resistance up to the arrester  ÂPull the protective transport cap straight out from the holder ATTENTION Do not switch on the device when the transport cap is attached The heat development of the modeling light could cause a fire Protective glass cover ATTENTION Make sure that the flash tube and modeling light do...

Страница 14: ...bserve all safety precautions Replacing the flash tube is described in detail in the chapter on maintenance see Replacement of flash tube on page 20 Inserting halogen lamp for modeling light The halogen lamp for the modeling light is plug in style Ob serve the following instructions when inserting the enclosed halogen lamp Note Avoid handling the lamp with your bare hands to prevent con taminating...

Страница 15: ...sheet before connecting the compact flash unit Compact flash units must only be connected to a grounded power supply The type label is located at the bottom side of the housing The compact flash unit Integra Mini 300 is solely approved for use with 115 V 230 V 50 60 Hz operation It features Multivoltage technology which means the unit auto matically adjusts to the applicable voltage Fuse protectio...

Страница 16: ... VISIT International GmbH Fuse protection device The inside of the unit contains a built in fuse When this fuse responds the unit is damaged ATTENTION Only authorized dealers may replace this fuse see 10 Custo mer service points on page 25 ...

Страница 17: ...inks slowly and the light output of the modeling light is proportional to the flash performance output One more push of the key turns the mode ling light off If you press the key for one second the AUTORED function is activated see below no matter what mode you are currently using Automatic modeling light reduction AUTORED The compact flash unit s modeling light is equipped with an energy saving m...

Страница 18: ...put range of 6 f stops p increases the output q reduces the flash unit s output A short push on the touch key changes the output in 0 1 f stop increments A longer push on the touch key changes the output in full f stops The LED display 3 shows the selected settings from 5 0 lowest output to 10 maximum output Note When the performance output is reduced to a lower setting the stored energy has to be...

Страница 19: ...lease contact the camera s manufacturer before using a non standard camera for such purpose Synchronization via slave The built in slave 9 triggers the flash when light from another flash is detected slave mode This mode of operation is activated deactivated by using the touch key SLAVE 14 The active setting is indicated via LED 11 above the touch pad The slave is an impulse photo cell It only tri...

Страница 20: ... of flashes The range of the counter is up to 9999 The double digit LED display 3 indicates the number in two steps The numbers from 00 to 99 are shown in the first setting The two additional digits are shown when pressing the key p 5 The touch keys p 5 and q 4 allow you to cycle through the double digit settings Example 2 Setting 1 Setting Total 00 22 22 flashes 21 47 2147 flashes 01 01 101 flash...

Страница 21: ...uipment in regular inter vals Compact flash units generators and accessories must be inspected in regular intervals to ensure safe operation An annual inspection of such devices ensures safe operation and retains equipment value Replacing the fuses ATTENTION Fuses must not be patched up or otherwise bypassed Only use spare fuses that meet the below listed requirements and have a fast response rati...

Страница 22: ...The tilting bracket 18 of the compact flash unit contains additio nal spare fuses Refill your fuse supply and replace the missing spare fuse as soon as possible Replacement of flash tube The flash tube of the compact flash is plug in style In case of a defect it can be replaced by the operator ATTENTION Turn the unit off and disconnect it from any power supply before replacing the flash tube Wait ...

Страница 23: ...D D A B 0 5 mm  ÂUnwind the ignition wire B from the connector pin C  ÂCarefully pull the flash tube A out of the plug in base D  ÂInsert a new flash tube of the proper type into the plug in base D and push the flash tube into position until the arres ter engages  ÂNow pull out the flash tube approximately 0 5 mm so that the glass body can expand when heating up  ÂWind ignition wire B around ...

Страница 24: ... Please use cotton gloves  ÂRemove the protective glass cover see Protective glass cover on page 11  ÂCarefully remove the lamp from the plug socket  ÂInsert a new lamp of the correct type Please make sure the lamp is properly secured when replacing the modeling light see Replacing the fuses on page 19 Maximum modeling lights to be used are 300W G6 35 115V or 300W G6 35 230V The modeling light ...

Страница 25: ...t output covered air vents ill fitted reflectors or a defective ventilator check by listening  ÂKeep the unit switched on so that the ventilator continues to cool the flash unit Switching off the modeling light can improve things The error message disappears as soon as the unit has cooled off again Unit related errors This error code indicates a severe problem The problem can only be corrected by...

Страница 26: ...ve glass covers and de fective power cables are excluded from any warranty The warranty includes replacement of faulty parts and the time required for installation by a qualified technician Note You may send the unit free of charge to one of the customer service points see 10 Customer service points on page 25 Please include a short description of the defect Disposal The packing materials need to ...

Страница 27: ...press service HENSEL VISIT International GmbH Robert Bunsen Str 3 97076 Würzburg Tel 49 0 931 278 810 Fax 49 0 931 278 815 0 E Mail info hensel de Service points listed in the Internet Additional national and international service and distribution addresses can be found on the web page of HENSEL VISIT International www hensel de ...

Страница 28: ...gle coating Halogen lamp for modeling light Item No 128 300 W 230 V Item No 1280 300 W 115 V Reflectors and soft boxes With small connector diameter 10 cm for EH Expert Integra line Umbrellas Spare fuses Item No 9412400 Safety fuses F 4 A H Sync cable different length Radio remote Strobe Wizard Plus Profoto Air Arresting cable Item No 769 Additional information concerning accessories can be found ...

Страница 29: ...count 18 E Energy saving mode 15 F Flash ready display 15 Flash tube 7 8 9 12 20 26 Fuses 10 13 14 19 H Halogen lamp 12 13 23 L Listing 6 13 P Performance adjustment 16 Photo cell 10 17 Power voltage 5 9 13 Protective glass cover 11 21 23 S Safety fuse 13 Scope of delivery 8 Synchronization 17 18 ...

Страница 30: ...User manual Integra Mini 300 28 HENSEL VISIT International GmbH 13 Declaration of Conformity for Electromagnetic Compatibility and Safety ...

Страница 31: ......

Отзывы: