User Manual eFLASH 250
HENSEL Studiotechnik
26
8:
3.15 AM / 6.3 AM
Replacement of fuses
In case of a broken fuse 8 replace fuse only, when the unit is
switched off and separated from the mains outlet.
Attention:
Never repair or bridge fuses. Only use fuses with the required
value (see imprint next to fuse 8): 3.15 AM for 230V units and
6.3 AM for 115V units.
Replacement of modeling lamp
Replace modeling lamp only during unit is switched off and
unplugged from the mains outlet.
Depending on the mains voItage the following modeling lamps
are allowed to be used (maximum value):
230VAC: 150W/230V/Socket G6.35 Halogen (Code 723)
115VAC: 150W120V/Socket B15d Halogen (Code 7010)
Wait till modeling lamp has cooled down and then pull it out
and replace the modeling lamp with a new one.
Replacement of flashtube
eFLASH is equipped with a user replaceable flashtube.
For replacement of flashtube switch off the unit, separate it
from the mains outlet and wait for at least 15 minutes.
Handle flashtube with care because of the high pressure inside.
Caution: In case of a damaged flashtube glass the electrodes of
the tube must not be touched in any case! In this case it is a
must to use isolated pliers for pulling out the flashtube!
First unwind the ignition cable from the connection pin of the
ignition. Then pull out flashtube and replace it with a new one.
Finally wind the ignition cable and reconnect it with the
connection pin.
You must make sure that the appropriate flashtube is used.
Please order from HENSEL: Flashtube, user replaceable, for
eFLASH Compact, single coated, Code No. 9450205.
Regular inspection
National safety regulations require regular inspection and
maintenance of electrical systems and appliances. Compact
flash units and accessories must be regularly checked for safe
operation. Yearly inspection of the appliances serves the safety
of the user and protects your investment in the system.
Содержание eFLASH 250 Compact
Страница 1: ...e anleitung Bedienungs manual User Kompaktblitzgerät Compact Flash Unit FLASH 250 ...
Страница 31: ......