5
Jan. 2014
The unit should be placed on a supportive structure or shelf so the
entire bottom of the unit is evenly supported, and also, where the
pans can be removed without interruption and easy loading and
unloading of product. For proper operation, the cabinet must be
level.
Access to the controls are on the side of the unit. The controls do not
need to be accessed for normal operation.
2-4.
ELECTRICAL
CONNECTION
The data plate, located on the side of the unit on the MPC-21L &
222, specifies the correct electrical supply. The unit requires a
grounded receptacle with a separate electrical line protected by a
fuse or circuit breaker of the proper rating. Electrical code may also
require GFCI protection.
The units are supplied with a 4 foot (274.3 cm) power cord.
Refer to the table below for electrical ratings:
Product Number
Volts
Watts
Amps
MPC-21L
120 110 .92
MPC-222
120 400 3.3
MPC-21L
230 110 .47
MPC-21L
230 400 1.74
(FOR EQUIPMENT WITH CE MARK ONLY!)
To prevent electric shock hazard this appliance must be
bonded to other appliances or touchable metal surfaces
in close proximity to this appliance with an equipotential
bonding conductor. This appliance is equipped with an
equipotential lug for this purpose. The equipotential lug is
marked with the following symbol
To avoid electrical shock, the cabinet must be
adequately and safely grounded (earthed) according
to local electrical codes.
2-3.
LOCATION
Содержание Wendy's MPC-21L