3-13.  CLEANING

 

11.  Add approximately 8 ozs. (0.24 liters) of distilled 

 

 

THE FRYPOT(S)

 

 

vinegar.  Use the Clean-Out Mode (see section 3-14), or 

(Continued) 

 

bring the solution back up to 195

°

 F (90.5

°

 C). 

 

 

 

 

12.  Using a clean brush, scrub the interior of frypot.  This 

         

  

 

 

 

 

neutralizes the alkaline left by the cleaning compound. 

 

 

 

13.  Drain the vinegar rinse water and discard. 

 
 

14.  Rinse down the frypot using clean, hot water. 

 
 

15.  Thoroughly dry the drain pan and the frypot interior. 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

        

 

 

 

Make sure the inside of the frypot, the drain valve    

 

 

 

 

 

opening, and all the parts that come in contact with    

 

 

 

 

new shortening are as dry as possible. 

 
 

16.  Replace the clean filter screen assembly in the drain   

 

 

 

 

pan, replace cover, and install drain pan under fryer. 

 
 

17.  Refill the frypot with fresh shortening. 

 
 

Henny Penny has the following cleaners available: 

 

 

Foaming Degreaser - Part no. 12226 

 

 

 

 

 

PHT Liquid Cleaner - Part no. 12135 

 

 

 

 

 

PHT Dry Powder Cleaner - Part no. 12101

 

 

 

See your local distributor for details. 

 

3-14.  CLEAN-OUT MODE

 

When heating the cleaning solution and vinegar solutions,

 

   

 

turn the POWER switch to the ON position.  When the fryer  

     

starts the Melt Cycle, press and hold            then  

     

 

     

“CLEAN-OUT ?”, “1=YES  2=NO” shows in display.   

 

     

Press            to start Clean-Out Mode.  The fryer displays  

 
     

“*CLEAN-OUT MODE*” and heats up to a preprogrammed  

     

temperature, up to 195

˚

F (91

˚

C), then automatically begins a  

     

preset timed countdown.  Use the                  if necessary, to adjust  

 
     

the temperature and keep the cleaning solution from boiling over.   

 
     

Once the timed countdown is complete and display shows   

     

“CLEANING DONE”, turn power switch to off position and drain  

     

cleaning solution from the frypot. 

     

 

     

Refer back to the Cleaning the Frypot procedures for more  

     

detailed instructions. See Special Program Modes SP-20 and SP- 

     

21 to preset the temperature and time. 

 

 
3-20 

 

 

 

 

 

 

 

      

     207

 

Содержание OEA

Страница 1: ...proper temperature for dropping product into the frypot 3 1 3 The timer buttons are used to start and stop Cook Cycles 3 1 4 The idle buttons are used to start an Idle Mode which reduces the temperatu...

Страница 2: ...Model OFE OFG OEA OGA 341 342 Figure 3 1 3 2 408 1 4 3 3 2 2 6 4 7 5 8 9...

Страница 3: ...to display the temperature of the shortening if the temperature exceeds 425 F 218 C the display reads E 5 FRYER TOO HOT 3 2 3 Once the fryer is out of the Melt Mode this LED lights signaling the opera...

Страница 4: ...t associated with each product Window selection button the menu card strip is located behind the decal 3 2 11 Product Select Used to stop Cook Cycles and also to stop the quality Buttons timer at the...

Страница 5: ...Model OFE OFG OEA OGA 341 342 12 1 2 3 4 5 6 7 12 8 9 10 9 11 Figure 3 2 903 3 5...

Страница 6: ...low grade shortenings have a high moisture content and will cause foaming and boiling over Wear gloves to avoid severe burns when pouring hot shortening into frypot Shortening and all metal parts tha...

Страница 7: ...ey are activated The above procedures should be followed to restart the open fryer and if the shut down is repeated a qualified technician should be notified The Melt Cycle may be bypassed if desired...

Страница 8: ...ay be set started or stopped without affecting the other 11 At the end of the Cook Cycle a tone will sound and the display flashes DONE Press button and lift the basket from the shortening Timer Progr...

Страница 9: ...controls now are reset to factory parameters the time set to 0 00 and temperature 190 F or 88 C 4 Press and LOCK or UNLOCK shows in the displays Use to choose LOCK or UNLOCK 5 Press and FRYR shows in...

Страница 10: ...aches 230 F 110 C the control enters the Heat Cycle and heats the shortening until the temperature setting is reached The gas open fryer has several safety devices which shuts down the gas supply when...

Страница 11: ...amage to the basket or lift mechanisms could result 6 Thoroughly stir shortening to stabilize the temperature throughout the frypots 7 Once the shortening temperature has stabilized at the setpoint te...

Страница 12: ...irst minute of cooking in case the wrong product button was pressed 11 The display shows either dashes or the product name depending on the Special Program setting SP 10 If a Quality Time was programm...

Страница 13: ...shortening lower the temperature to 275 F 135 C or lower when the fryer is not in immediate use Deteriorated shortening smokes badly even at lower temperatures 3 Taste the cold shortening daily for si...

Страница 14: ...e cover lines up with the drain before opening the drain Failure to follow these instructions causes splashing of shortening and could result in personal injury Surfaces of fryer and baskets will be h...

Страница 15: ...d pump all of the shortening out of the filter drain pan and back into the frypot Figure 3 8 IF SHORTENING FLOW IS SLOW FROM THE FAUCET IT S POSSIBLE THAT THE FILTER CONNECTION AT THE UNION ON THE FIL...

Страница 16: ...filter screens Fold the open end of the envelope and clamp with retaining clips so that crumbs cannot enter See Figure 3 9 Figure 3 9 2 Pump shortening until no shortening is coming from nozzle 3 11 F...

Страница 17: ...ain pan 4 Wipe the shortening and crumbs from the drain pan Clean the drain pan with soap and water Thoroughly rinse with hot water 5 Unthread the suction standpipe from the screen assembly 6 Remove t...

Страница 18: ...fryer as it will go and the cover in place Be sure the hole in the cover lines up with the drain before opening the drain Failure to follow these instructions causes splashing of shortening and could...

Страница 19: ...e cleaning solution in the frypot starts to foam and boil over immediately turn the power switch to OFF or damage to components could result Do not use steel wool other abrasive cleaners or cleaners s...

Страница 20: ...has the following cleaners available Foaming Degreaser Part no 12226 PHT Liquid Cleaner Part no 12135 PHT Dry Powder Cleaner Part no 12101 See your local distributor for details 3 14 CLEAN OUT MODE W...

Страница 21: ...er the display and LED shows READY To Shutdown burner 1 Turn the power switch to the OFF position 2 Rotate gas valve knob to the OFF position 3 16 HIGH TEMPERATURE This high temperature limit control...

Страница 22: ...Filtering of shortening Daily 3 4 loads Changing of shortening When shortening smokes foams up violently or tastes bad Changing the filter After 10 12 filterings or when envelope envelope is clogged w...

Отзывы: