4
5
March 2019
7
-2
ERROR CODES
DISPLAY
CAUSE
CORRECTION
“E-4”
Control board overheating
Turn switch to OFF position, then turn switch back to ON;
if display shows “E-4”, the control board is getting too hot;
check the louvers on each side of the unit for obstructions
“E-5”
Oil Overheating
Turn switch to OFF position, then turn switch back to ON;
if display shows “E-5”, the heating circuits and temperature
probe should be checked
“E-6A”
Temperature probe open
Turn switch to OFF position, then turn switch back to ON;
if display shows “E-6A”, the temperature probe should be
checked
“E-6B”
Temperature probe shorted
Turn switch to OFF position, then turn switch back to ON;
if display shows “E-6B”, the temperature probe should be
checked
“E-10”
High limit
Allow heating elements to cool (15-20 minutes) and reset high
limit by pressing down and releasing raised side of the switch for
the vat that is not operating; switches are located behind right
door; if high limit does not reset, high limit must be replaced
“E-15”
Drain switch
Make sure drain handle is completely turned to the close
position; if E-15 persists, have drain switch checked
“E-21”
Slow heat recovery
Have a certified service technician check the fryer for correct
voltage to the unit; have the contactors and heating element
checked; have unit checked for loose or burnt wires
6-3
In the event of a control system failure, the digital display shows an error
message. The message codes are shown in the DISPLAY column below. A
constant tone is heard when an error code is displayed, and to silence this
tone, press any button.
Содержание GVE-071
Страница 2: ......
Страница 4: ......
Страница 14: ...8a July 2014 2 9a DIMENSIONS Casters adjustable up to 1 562 in 40mm ...