Troubleshooting
89
Operating instructions
Error no.
Fault message displayed
Description
Action
710
•
Vapour sensor defective
Steam elimination is now controlled
solely by the software. This results
in higher water consumption.
•
Contact Customer service
•
Water pressure too low
As continuous fault message
•
Open the water valve
•
If water valve not closed, contact
customer service
•
Water pressure too low
As sporadic fault message
•
Activate fewer appliances simul-
taneously in the kitchen.
•
Contact Customer service
•
No water in the siphon
The siphon is insufficiently filled
with water.
•
Open the water valve
•
2 l (0,53 gal) Pour water into the
cooking chamber
•
If the fault message does not dis-
appear, contact customer service
•
Unit restarted after power
failure
If there was no power failure in the
kitchen, an operating error may be
involved. For instance,
unintentionally switching on and off
while a cooking program was
running.
•
Power failure < 1 minute
•
Confirm the power failure mes-
sage
•
Continue the cooking program
•
No cleaning necessary
•
Power failure > 1 minute
•
Cooking program cancelled
•
Run the cleaning cycle
•
WaveClean cancelled
•
Heed the explanations and instructions in the "Automatic cleaning
(WaveClean)" chapter
6.3 Nameplate
When contacting customer service, please always provide the following
data from the nameplate:
Serial number
(SN)
Type number
(TYP)
FM05-161-G
Содержание FlexFusion SpaceSaver Plus FSE- 610