Operating instructions
4.6.8 Ready2CookSetting
a
c
b
d
e
Image: Window for setting the "Ready2Cook" parameters
a Rollers
d
Read button
b
Write button
e
Display
c
Keyboard button
Prerequisite
Unit function
menu open
1. Tap the
Settings
field.
2. Enter PIN 111 and confirm it.
3. Tap the
Parameter settings
field.
The
Parameter settings
menu is displayed.
4. Use a swipe gesture to set the rollers to the desired value.
The name of the selected parameter is displayed.
5. Tap the
Read
button.
The current values displayed.
Switch the function on or off as necessary.
6. Use the keyboard to delete the current value.
7. Use the keyboard to enter a new value.
8. Tap the
Write
button.
The displayed value is adopted.
The
Ready2Cook
function is set.
4.6.9 Steam Exhaust SystemUsing the (SES)
INFORMATION
The
Steam Exhaust System (SES) automatically extracts the steam out of the
cooking chamber.
It is on by default and can be switched off for individual programs.