Operation
Electric
Space$aver
™
39
Space$aver
™
1
Settings
2
No.
3
Standard
setting
4
Setting range
5
Explanation
Time/Date
000
Local time
operator
Time/date
Automatic change between summer time / winter
time
See parameter No. 144 for date format
Light flashes
023
On
On/Off
"On” means that when cooking is completed, the
light will flash in addition to the buzzer sounding.
The duration of the flashing matches the buzzerr, i.e.
if thebuzzeris set to “0”, the light will not flash (even
if flashing is activated).
Preheating
factor %
082
15 0-30%
Increase the preheating factor if fully loaded with
large amounts (roasts, bread loaves) so that the
temperature does not drop too severely.
Water
maintenance
litre
076
0
0-90,000 L in
100-L
increments
For external water-treatment systems, for connection
to soft water only. Confirm receipt of the mainte-
nance request with the "Read" button. The mainte-
nance request is repeated until maintenance occurs
and the "Done" button is finally pressed.
Date format
144
DD.MM.YY
YY
DD.MM.YYYY
YYYY/MM/DD
MM/DD/YYYY
TT = Day
MM = Month
JJJJ = Year
12 or 24 hour clock
Temperature
display
006
in °C
°C/°F
The temperature display in °F is not linked to the
English display text.
Cookbook
097
Free
Free
Programs in the Cookbook can be changed, deleted,
or saved.
Locked:
Programs in the Cookbook cannot be changed,
deleted, or saved. However, changes can be made
during cooking.
Fully locked
Changes cannot be made to the Cookbook or during
the cooking process.
Time delay
fan
032
Off
Off/On
When “On”, the fan runs during the time delay to
cool the oven chamber with a block of ice in the
bottom drawer.
For this purpose, place the perforated container in
the closed container, fill with approximately 4 litres
of water and allow to freeze. Insert the ice block into
the perforated container at the lowest level. This
allows a temperature of 57°F to be maintained for up
to 6 hours
Cooling
water
024
Standard
Minimum -
Maximum
“Minimum” setting: Minimum water consumption
but higher condensation temperature and greater
amount of waste steam.
“Maximum” setting: Maximum water consumption
but lower condensation temperature and less waste
steam.
Содержание ECS-605
Страница 2: ......
Страница 4: ......
Страница 10: ...Operating Manual Contents 10 ...
Страница 12: ...Electric Space aver 12 Space aver Appliance description ...
Страница 29: ...Operation Electric Space aver 29 Space aver ...
Страница 30: ...Electric Space aver Operation 30 Space aver ...
Страница 50: ...Electric Space aver 50 Additional functions Space aver 50 ...
Страница 51: ...Electric Space aver 51 Additional functions Space aver ...
Страница 52: ...Electric Space aver More functions 52 Space aver ...
Страница 60: ...Electric Space aver Practical tips 60 Space aver ...
Страница 73: ......