![HENNING MSM 12 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/henning/msm-12/msm-12_operating-instructions-manual_2124103008.webp)
Mobile Rope Measurement MSM 12
Henning GmbH
Page 8
2.0 / 3.2009
7
Operation
The handling of the mobile rope load meter MSM12 is described below. For opera-
tion of the MSM12 using the optional software refer to the software operating instruc-
tions.
7.1
Installation of the rope load sensors LSM
In each LSM rope a rope load sensor must be installed as described in chapter 6.
Take care that you assign the connections of the rope sensors at the MSM12 in con-
tinuous and ascending order, starting with connection 1. For the use of the rope load
wizard it is important that you do not skip any connections.
7.2
Switching-on
In order to switch on the MSM12 mobile rope load meter please press the on/off
switch for minimum 3 seconds. The display now shows the Henning logo. After a
short time the display switches to the main display. The MSM12 is now ready for op-
eration.
To switch off please press the on/off switch for minimum 3 seconds again. The de-
vice switches off, the display lighting is extinguished. If the inserted batteries are run-
down, the MSM12 switches off automatically. The approaching switch-off is indicated
30 seconds in advance by a flashing weight display.
In order to avoid a damage of the MSM12 spent batteries should be replaced as
soon as possible by new ones. In order to guarantee the data storage of the real-time
clock of the MSM12 it should not be left more than 20 minutes without voltage sup-
ply. In the switched-off condition the run-down batteries supply the clock with voltage
for one week. The loads and adjustment records are stored in non-volatile memory in
the MSM12 and are maintained up to ten years without having to insert batteries.
7.3
Main display
Figure 1 shows the main display of the mobile rope load meter MSM12. In the upper
two lines of the main display the status bar indicator and the indication of the individ-
ual weight of each rope under the corresponding sensor number are displayed. Be-
low, in the centre, the total weight resulting from the individual weights is indicated. At
the right side and below the total weight three menu buttons
SAVE
,
CONFIG
and
ADJUST
are to be found which will be described in detail below. In the lower left-
hand corner the time and date are displayed.