Flux and Electrode Stabilizing Guide

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

After Exposure to Moisture a 

Sufficient Time to affect Weld Quality

 

 

 

Type (AWS

 

Air Conditioned 

Storage 

Before Opening

 

 

Dry Rod 

Oven Holding 

After Opening

 

Recondition 

Step 1

 

Rebake 

Step 2

 

180

°

±

 25

°

 

two hours 

240

°

±

 25

°

 

one hour 

Standard

 

EXX10 
EXX11 
EXX12 
EXX13 
EXX20 
EXX30

 

80

°

±

 20

°

 

60% 

±

 10% RH 

140

°

±

 30

°

 

Three hour total 

180

°

±

 25

°

 

two hours 

325

°

±

 25

°

 

one hour 

Iron

 

Powder

 

EXX14 
EXX24 
EXX27

 

90

°

±

 20

°

 

50% RH max 

140

°

±

 30

°

 

Three hour total  

180

°

±

 25

°

 

two hours 

700

°

±

 100

°

 

one-half hour  

Iron

 

Powder

Low 

Hydrogen

 

EXX18 
EXX28

 

90

°

±

 20

°

 

50% RH max 

400

°

±

 50

°

 

Two & one-half hour total 

180

°

±

 25

°

 

two hours 

600

°

±

 100

°

 

one-half hour 

Low

 

Hydrogen

 

EXX15 
EXX16

 

90

°

±

 20

°

 

50% RH max 

400

°

±

 50

°

 

Two & one-half hour total 

180

°

±

 25

°

 

two hours 

700

°

±

 100

°

 

one-half hour 

Low

-

Hydrogen

 

High Tensile

 

EXXX15 
EXXX16

 

90

°

±

 20

°

 

50% RH max 

400

°

±

 50

°

 

Two & one-half hour total 

180

°

±

 25

°

 

one hour 

350

°

±

 50

°

 

one hour 

Stainless

 

Inconel 

Monel 
Nickel 

Brasses 
Bronzes 

Hard Surfacing 

Special Alloys

 

90

°

±

 20

°

 

50% RH max 

225

°

±

 50

°

 

Two hour total 

Granulated

 

or

 

Agglomerated

 

Flux 

90

°

±

 20

°

 

50% RH max

 

240

°

 F 

±

 50

°

 

Not required 

700

°

±

 100

°

 

 

two hours 

 
CONTACT YOUR ELECTRODE MANUFACTURER FOR SPECIFIC INFORMATION INVOLVING 
CRITICAL OPERATIONS. 
 

Electrode coating should not be exposed to the rebaking temperature without first having been reconditioned at a lower 
temperature.  Failure to observe this rule will result in breakdown of electrode coatings. 

 

After rebake, lower temperature to 

holding level

 until reissue

.

Note:  In the HTS 

Stainless electrode 

groups, and 15 & 16 

type coatings, there can 

be a greater difference 

in the maximum 

temperature 

requirements for 

rebaking than those 
shown.  This can be 

handled by special 

request to the particular 

manufacturer involved. 

IMPORTANT: 

This table is offered as a 
guide to proper storage 
and oven holding 
temperatures for the 
most common electrodes 
in use today.  In 
addition, 
recondition/rebake 
procedures for electrode 
coatings that have been 
exposed to moisture for 
a sufficient period of 
time to affect the weld 
quality are included.  
Good judgment and the 
manufacturer’s 
recommendations should 
be your guide. 

Содержание K-450

Страница 1: ...Henkel Inc P O Box 1322 Hammond LA 70404 985 345 2171 www keenovens com...

Страница 2: ...vers only equipment manufactured by Henkel Inc and does not extend to transportation installation or replacement charges at the buyers facility nor does it apply to any other equipment of another manu...

Страница 3: ...meplate of the unit Check outlet to ensure proper grounding of the electrical cable Have a licensed electrician check the A C power outlet if you are not sure Use this unit for its intended purpose as...

Страница 4: ...from 150 F 37 8 C to 550 F 287 8 C Turn thermostat knob to desired temperature by aligning with red line on chrome bezel Pilot light indicates when power is supplied to the heating element The thermos...

Страница 5: ...f pilot light fails to operate replace thermostat IF OVEN OVERHEATS 1 If oven fails to cycle on and off and reaches a temperature above 550 F thermostat is faulty and needs replacing 2 If oven operate...

Страница 6: ...em and check rotation of knob When knob turns freely remove and tighten chrome mounting ring bezel 240 Volts 1000 Watts Grounding Plug NEMA 5 15P 9 Replace leg assembly being sure wiring is not crimpe...

Страница 7: ...Cord 301155 10 1 Elements 301027 301125 301129 11 1 Element Cover 12 1 Name Plate 450103 13 1 Strain Relief 301043 480V 1000W 120V 240V 480V 240V1000W 120V1000W Please state model number and serial nu...

Страница 8: ...r Stainless Inconel Monel Nickel Brasses Bronzes Hard Surfacing Special Alloys 90 F 20 50 RH max 225 F 50 Two hour total Granulated or Agglomerated Flux 90 F 20 50 RH max 240 F 50 Not required 700 F 1...

Отзывы: