10
The reservoir is depressurized when the depressurizing valve (1) is in
“OFF”
position
and pressure gauge (2) indicates no pressure.
•
Loosen the reservoir locking knobs (5) and remove lid (6).
•
Check that there is no condensed moisture at the bottle or the
sensor surface.
•
Place the bottle in the bottle holder (see the right figure).
•
Check that the product bottle inserted in the bottle holder is
pressed again the level sensor.
•
Insert the product feedline into the bottle and put on the lid.
•
Uniformly tighten the reservoir knobs by hand.
•
Set the depressurizing valve (1) to
“ON”
position (pressurize).
•
On the controller 97102, switch the reservoir to active with the button .
On the controller 97152 or RC15 switch the reservoir to active with button
5
Operation
5.1 First Operation
The automatic reservoir is depressurized when the power switch on the controller
97102, 97152 or RC15 is switched to the O (OFF) position or the tank pressure gauge
indicates no pressure.
In any case:
•
Set the depressurizing valve (1) to position (depressurize).
•
Check that the dispensing valve is connected correctly according to the instruction
manual.
Inserting the Product Bottle
Follow procedure as described in section 4.3.