Adjust the Level Set Point (General Procedure)
1.
Turn the adjustment screw clockwise until seated.
2.
Turn the adjustment screw counterclockwise 5 complete turns.
3.
Fill tank to desired switch level (with recirculating pumps on, if present).
4.
Turn adjustment screw slowly until the lamp changes state:
a.
If indicator is ON turn the adjustment screw slowly clockwise.
b.
If indicator is OFF turn the adjustment screw slowly counterclockwise.
The “Green” and “Amber” indicators are on the Control Point switch.
When one is ON the other is OFF. Adjusting the screw will toggle both
lights.
5.
Turn adjustment screw slowly in the opposite direction to change the
indicator state back.
6.
Perform number 4 and 5 a couple times stopping with the indicator just
turning OFF. For the Control Point switch, “Green” indicator will be ON and
“Amber” indicator will be OFF.
7.
Check switch point by adjust the tank fluid level down and up to change
indicator state. Note tank levels at the indicator state changes.
8.
For fine tuning switch point level, repeat steps 3 through 7.
9.
Repeat process for next highest process tank level.
5.5 One Point Level Control for Low Level Shut-Off for Drums, Totes, or Day Tanks
One point level control can be used with drums, totes, or day tanks for low level
shutoff of mixers or pumps. The bottom of the probe should be located 1” up from
the bottom of the container. The level control adjustment screw should be turned
full counterclockwise.
Use tubing in place of the immersion air probe when inserting into drums due to
the small drum openings. The tubing needs to be securely fastened to the foot
valve assembly for the chemical feed pump prior to insertion.
Содержание 2250048 REV
Страница 1: ...E CO Level Control 120 VAC One Two Three and Four Points Operating Manual ...
Страница 2: ......
Страница 24: ...20 9 Diagrams 9 1 2251341 REV E CO Level MSTR 1 PT electrical 9 2 2250048 REV E CO Level STD 1 PT electrical ...
Страница 25: ...21 9 3 2251340 REV E CO Level MSTR 2 PT electrical ...
Страница 26: ...22 9 4 2251339 REV E CO Level STD 2 PT electrical ...
Страница 27: ...23 9 5 8907225 Master Level Control Three Point electrical ...
Страница 28: ...24 9 6 8907224 Standard Level Control Three Point electrical ...
Страница 29: ...25 9 7 8907227 Master Level Control Four Point electrical ...
Страница 30: ...26 9 8 8907226 Standard Level Control Four Point electrical ...
Страница 31: ...27 9 9 Level Control Standard and Master Installation Drawing 8907228 ...