Thermal Printer C-56
Part No. 2 684 019
Rev. No. 4310715 eli
page
14
of
17
6.0 Technical Data
6.1 General Data
Dimensions:
Height-width-depth HxWxD (in mm): 184.5 x 129.5 x 169.5
For opening the printer, a free space of height H = 45 mm and width W = 60 mm
must be provided. Please refer to the dimensional sheets at www.hengstler.com.
Weight:
Net approx 0.56 kg
Operating Voltage:
a) +24 VDC ±5 %, SELV (EN60950)
Current consumption stand by 0.1 A, operation up to 6 A
Recommended safety fuse: 6 A, delayed-action
b) +12 VDC ±5 %, SELV (EN60950)
Current consumption stand by 0.1 A, operation up to 6 A
Recommended safety fuse: 6 A, delayed-action
UL - Certificate:
E174318
Interface:
a) Mini USB 1.1 industrial; cable length < 3 meters
Transmission rate: 1.5 MBit/s and 12 MBit/s
Printer graphics driver for Windows XP/7/8/10 and LINUX
USB – interface cable
b) Micro RS232; cable length <3 meters
Communication protocol: Hardware DTR/CTS, None
Baud Rate: 4800, 9600, 19200, 38400, 57600, 115200 (default)
Parity: Off (default), On
Data Bits: 8
Stop Bits: 1 (default), 2
RS232 – interface cable
Noise Level:
< 55 dB(A) according to ISO 3744
Operating Conditions:
For guaranteed printing quality (limit values in brackets)
Temperature: +5 °C to +50 °C (- 30°C to + 70 °C)
Humidity: 20 % to 80 % (90 %), no condensation
Storage Conditions:
Temperature: -40° C to + 85° C
Humidity: 5 % to 95 %, condensation not permitted
During storage and storage in transit, leave paper inserted between
thermal printhead and platen
Operating Reliability:
Printer mechanism: 100 km of paper, at a printing density of 12.5% or 100 million
dot pulses
MTTR: 1.5 minutes (module exchange)
All data refer to processing of the recommended paper quality, in a temperature
range appropriate to yield the guaranteed printing quality.