5
EN
3. Use and maintenance instructions
The machine is essentially composed by a main
structure, innerly composed by steel AISI 430. In-
side there are the switchboard and the vacuum
working station. It is recommended not to inter-
vene on the vacuum working inner part (just in case
of extraordinary maintenance, that must be carried
out by the manufacturer).
The sealing bar – to seal the bag at the end of the
cycle – is placed on the external part of the struc-
ture, front and below part of the machine, together
with the gasket, which defi ne the fi xed part of the
decompression chambers, where the bag is usually
placed to be packed.
The superior part of the decompression chamber
is fi xed on the mobile lid connected to the main
structure through two hinges. This system allows
to keep the bag blocked for a proper suction and its
following sealing.
WORKING PROCESS
• Take the machine out of its package, place it on
the working table and verify its stability.
• It is important that all four supports of the ma-
chine adhere to the surface, in order to get the
lid closed tight to the below part of the machine.
This way the correct working of the machine is
granted.
• It is recommended to keep the machine pack-
aging, in order to use it again in the future for
possible transfers.
• Clean the machine carefully before using it.
Clean the external structure with a humid rag
fi rst and then with a dry one; for the display, use
a dry rag only.
• It is strictly forbidden to use acid or caustic
products.
• Insert the plug into the socket.
• Switch the machine on, by turning the side
switch on I (only 297377).
• Keep the button ON/OFF (1) pressed for 2 seconds.
• The machine is ready to be used with time and
sealing settings used the last time.
4. Usage methods
VACUUM CYCLE WITH AUTOMATIC CYCLE
• By keeping the machine on, move the lid up.
• Insert the product inside the bag.
• Insert the bag into the decompression chamber
with the opening part in between the two black
gaskets.
• Check that the inner component of the bag does
not interfere with the sealing bar. Check that the
bag is not broken and placed steady on the seal-
ing top.
•
Low down the lid with a moderate pressure
on the two sides or, if present, on the central
handle. Keep the lid pressed for a few seconds
until the air starts to be sucked out. Then, re-
lease the lid.
• The machine will automatically starts its cycle
and the display will show the vacuum level by
lightening the LED lights.
• Once the vacuum is over, the sealing will fol-
low automatically. Once the sealing is over, the
pump stops working and the mobile lid opens
automatically.
• The machine is now ready to pack the bag.
Содержание 297377
Страница 23: ......