background image

Henden 3 Speed Pump Owners Manual

OWNERS MANUAL

3. START UP

3.1 Pre-start up checklist

•   Low Speed setting is compatible with  

other pool equipment 

•  The pump is installed in a safe and dry environment 

•   The pump enclosure has adequate drainage  

in the event of leakage 

•  Any transport plugs are removed 

•  The pipework is correctly sealed and supported 

•  The pump is primed correctly 

•  The power supply is correctly connected 

•  All steps have been taken for safe operation 

•  The filter has been plumbed with 40/50mm pipe 

 

To realise the best energy efficiency from your pump, 
please follow these installation recommendations: 
•  Suction pipe length should be kept as short as possible 
•   Install a 450mm long straight pipe horizontally into the 

front of the pump

•  Minimise the number of bends in the plumbing

3.2 Starting the Pump

To operate efficiently and prevent pump damage there 
must be a free flow of water to and from the pump. Before 
starting ensure that:
•  All pipework is correctly sealed
•   The pool/spa water level is at the correct height (at least 

halfway up the skimmer base)

•   All appropriate valves are open and there is nothing 

preventing the flow of water through the system

The Henden 3 Speed Pump motor has 3 pre-set speed 
settings: Eco Flow, Mid Flow and High Flow. It will always 
start on High Flow setting to aid priming and after 2 
minutes will automatically revert to the last used speed 
setting. The pump can further be adjusted to run at 
different speeds between the three speeds.

1.  First prime the pump by removing the strainer basket 

lid and filling the strainer basket area with water. 
Replace the lid, ensuring that it seals on the large 
o-ring.

2.  Connect to the power supply and switch on.
3.  Allow the pump to run, so that any air trapped may be 

expelled. It will start in High Flow mode (high speed) for 
2 minutes in order to prime effectively.

4.  If prime is not established within approximately two 

minutes, as evidenced by a strong flow of water and 
no bubbles returning to the pool, switch off the pump 
and repeat the procedure. Continued evidence of air 
under the strainer basket lid indicates an air leak in the 
suction piping which should be rectified to avoid pump 
damage.

For optimum pump performance, the strainer basket 
housing should always be full of water and free from air 
bubbles. The water level of the pool should always be 
maintained to at least halfway up the skimmer box, which 
will ensure water is supplied to the pump at all times. From 
time to time it may be necessary to re-prime the pump. 
This should be carried out as described above.

NOTE: During high speed start up, the 
LED for the last set speed will flash. 

Never run the pump dry. Running the 
pump with no water may damage the 
mechanical seals, causing leakage 
and flooding. Dry running damage 
and associated damage is not covered 
under warranty.

6

 

|

 

HENDEN

 INSTALLATION & OWNERS MANUAL

Содержание H83SP

Страница 1: ...nowledgeable in swimming pool plumbing requirements following the installation instructions provided in this manual Henden 8 3 Speed Pump H83SP A joint government and industry program Henden Pump Mode...

Страница 2: ......

Страница 3: ...N 5 OWNERS MANUAL 3 STARTING UP 6 3 1 Pre start up Checklist 6 3 2 Starting the Pump 6 4 LOW ENERGY OPERATION 7 4 1 Using your Henden 3 Speed pump with a Henden Salt Water Chlorinator 7 4 2 Operating...

Страница 4: ...s damaged it must be replaced by Henden or the manufacturer with genuine Henden spares This Henden 3 Speed Pump incorporates motor overload detection designed to protect the motor from overheating If...

Страница 5: ...any humps and hollows which cause suction difficulties The discharge piping from the pump outlet should be connected to the inlet connection on the swimming pool filter usually at the filter control...

Страница 6: ...minutes will automatically revert to the last used speed setting The pump can further be adjusted to run at different speeds between the three speeds 1 First prime the pump by removing the strainer ba...

Страница 7: ...he flow rate is sufficient to cover your cell plates completely at all times of operation For other chlorinators please refer to the relevant installation and operating instructions 25 TOTAL HEAD m 20...

Страница 8: ...d is tripped The pump has an in built thermal overload which will re set automatically after the motor has cooled following an overheating period Determine the cause of the overload tripping and recti...

Страница 9: ...ould it be necessary to remove the pump follow these instructions 1 Switch off the power and remove the plug from the power source 2 Close the water valves on the pool return and the pump inlet pipewo...

Страница 10: ...IRING MUST BE CARRIED OUT BY AN AUTHORISED ELECTRICIAN 10 HENDEN INSTALLATION OWNERS MANUAL Routine Maintenance tasks to maximise the life of your pool equipment personal safety use this checklist onc...

Страница 11: ...r advertised failure to properly follow the provided installation and operating instructions failure to carry out maintenance corrosive or abrasive water or other liquid lightning or high voltage spik...

Страница 12: ...P N 403212 2...