3.0
vOLTAGE CHAnGE
Your generator can be connected at 230/400V three-phase.
The generator is set at the factory for a 400V three-phase voltage.
For safety double check the sticker placed at the end of the input
cable.
Should it became necessary to use an input current at 230V simply
follow these instructions (only on models with this option):
•
Put the main switch in the “OFF” position, disconnect the sup-
ply cable from the mains.
•
Remove the right side panel
•
Change the connections on the voltage change board, fol-
lowing the instructions on the label (see Fig. 1)
•
Make sure that the nuts holding the bridges are securely ti-
ghtened.
•
Re-assemble the right side panel.
For safety reasons and to avoid affecting the cooling conditions, do not
work with the side panels partially opened or completely removed.
FIG. 1
4.0 ASSEMBLY
4.1 HANDLE AND WHEELS ASSEMBLY (fIG. 2)
•
Unpack the welder.
•
Insert the axle (B) through the holes at the rear of the
welder, slide the wheels (A) as shown in picture 2 and fix
them using the supplied rings (C);
•
Mount the handle (F) on the supports (D-E) and fix them to
the front panel using the provided screws (G-H);
•
Place the gas cylinder on the cylinder support and fix it
with the chain provided: the cylinder must be equipped
with pressure regulator. For the connection between the
generator and the separate wire feeder use the intercon-
nection cables provided.
•
Place the power source in a well ventilated area: dust,
grit or any other thing that may obstruct the air intake
and output vents can prevent the ventilation and good
operation of the welder.
4.2 TORCH LEAD ASSEBLY (fIG.3)
•
Plug the torch hose into the socket on the front of the wel-
der and secure by hand screwing in the threaded con-
nection.
FIG. 2
FIG. 3