INSTALLATION INSTRUCTIONS AND START-UP
INSTALLATION
For installation, electrical connection can be carried out with plug and socket 2 x 16 + T to be installed
by the user.
Connect the suction device by inserting the flexible hose to the filler neck, which in its turn is connected
to the collector.
It is advisable to protect the unit from moisture.
WARNINGS
Before installation, check the mains voltage.
COMMISSIONING
It is recommended to include the use of the device by the following environmental conditions:
• The environment operating temperature of the machine has to be between -10 ° C and 60 ° C
• The humidity of the indoor environment in which the work is carried out must be between 0% and 90%
Recommendations / Instructions:
• The elimination/removal of any waste materials should be carried out according to the regulations
• For cleaning or replacing the filters using the mask and protective gloves.
Description of manual controls
The only manual controls on mechanical PFE air cleaner: SWITCH ON and the light is ON, SWITCH
OFF and the light turns OFF
Before startup, check that the mains voltage is in accordance with what is set at installation time.
ATTENTION:
Both container and the connected metal structures should be thoroughly grounded, as required by safety
regulations.
For this reason, an effective of grounding line must be available near the PFE equipment.
The test is carried out at manufacturer’s premises, prior to shipment.
STARTING
After carrying out the above checks, turn on the mechanical purifier on the panel and connect the collector
element.
FUNCTIONING
NORMAL USE
The PFE air cleaner has been designed and built for occasional use.
The air cleaner should be used exclusively for mechanical exhaust of smoke, fine dust, gas, gaseous pol-
lutants in low concentrations through a torch hood or flexible hose, the end of which is connected with an
appropriate filler plug placed on the door of the equipment.
Remember that: the law allows recycling in environment only if it is for occasional welding operations.
The manufacturer is not liable for any use other than as described.
Not to do
• Do not remove the air cleaner filter panels while the equipment is working.
• In general, do not dismantle nor remove any part if the mechanical air cleaner is on use or connected
to the power supply
• Do not insert the power cord in the closures of the panels
• Do not tamper with the components of the electrical panel
• Do not run the vacuum cleaner while the suction nozzle is closed
• Do not pick up liquids
• Do not place hot objects on the machine surface (eg cigarette butts)
IMPORTANT NOTE
THE EQUIPMENT SHOULD NOT BE USED IN EXPLOSIVE ATMOSPHERE