![Helo ROCHER Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/helo/rocher/rocher_instructions-for-installation-and-use-manual_2122373008.webp)
8
Table 1
Input Sauna heater's Fuse Sauna heater's Fuse Sauna heater's Fuse
connection cable connection cable connection cable
H07RN-F H07RN-F/ H07RN-F/
60245 IEC 66 60245 IEC 66 60245 IEC 66
kW mm
2
A mm
2
A mm
2
A
400 - 415V 3N~ 230 V 3~ 230 - 240V 1N~ / 2~
6,8 5 x 1,5 3 x 10 4 x 2,5 3 x 16 3 x 6 1 x 35
9,0 5 x 2,5 3 x 16 4 x 6 3 x 25 ------- -----
10,5 5 x 2,5 3 x 16 4 x 6 3 x 35 ------- -----
3.5 Locating the connecting box for connection cable in the sauna room
200
m
m
500
m
m
A
A
3.
2.
1.
500
m
m
Image 2
A = Speficed minimum clearance
1.
Recommended location for the connecting box
2.
Silumin box recommended in this area.
3.
This area should be avoided. Always use a silumin box.
In other areas, use a heat-resisting box (T 125 °C) and heat-resisting cables (T 170 °C). The connecting
box must be clear of obstacles. When installing the connecting box to zones 2 or 3, refer to the
instructions and regulations of the local energy supplier.
3.6 Sauna heater
safety clearances
Table 2
Sauna room Safety clearances
min.
H A D F
kW m
3
m
3
mm mm mm mm ca.kg
6,8 5 9 1900 60 60 770 100
9,0 8 13 1900 60 60 770 100
10,5 9 15 1900 60 60 770 100
Inp
u
t
mi
ni
m
i
ma
xi
m
i
Heig
h
t m
in
on
the
side
s
at the
fr
ont
to the
ceilin
g
ad
equ
ate
am
oun
t of
sto
nes