Electric sauna heater:   
                  

1118-700-04 

1118-900-04 
1118-1050-04 

 
 

Contactor box: 

WE – 3  

400V – 415V 3N~  max 9 kW 

WE – 4 

400V – 415V 3N~  max 15 kW 

WE – 4 – 1  230V – 240V 1N~ / 2~  max 8 kW 

WE – 4 – 3  230V 3~  max 9 kW 
WE – 5 – 3  230V 3~  max 15 kW 

 

 

 

Connectable to the following control panels: 
 

1601-12  (Control panel RA 12 Digi II) 

1601-13  (Control panel RA 13 Digi I) 
1601-16  (Control panel RA 16 Easy) 

1601-18  (Control panel RA 18 Midi) 

 

 

 

 

 

314  SKLT 47

-2

 A 

GENUINE SAUNA & STEAM

 

Содержание ROCHER

Страница 1: ...3N max 9 kW WE 4 400V 415V 3N max 15 kW WE 4 1 230V 240V 1N 2 max 8 kW WE 4 3 230V 3 max 9 kW WE 5 3 230V 3 max 15 kW Connectable to the following control panels 1601 12 Control panel RA 12 Digi II 16...

Страница 2: ...Locating the connecting box for connection cable in the sauna room 8 3 6 Sauna heater safety clearances 8 3 7 Switch diagram 10 3 8 Installing the support for heating elements 12 3 9 Spare parts for...

Страница 3: ...ore heat such as tile and stone surfaces must be insulated It is recommended to use wooden panel cladding inside the sauna room If there are heat storing elements in the sauna room such as decorative...

Страница 4: ...ift the support bar s locking plate up from its normal position Lift off the support bars Pile stones up to the Helo marker Reinstall the support bars Install the support bars as above in the reversed...

Страница 5: ...aced on the sauna heater because they might fall trought the heater s vertical beams The warranty does not cover defects resulting from poor ventilation caused by small and tightly packed stones Struc...

Страница 6: ...on page 8 for a suitable fuse size A and the correct diameter of the power supply cable mm for the sauna heater in question 5 Conform to the safety clearance around the sauna heater as specified in Ta...

Страница 7: ...ated within the minimum safety clearance specified for the sauna heater The maximum height for the connecting box is 500 mm from the floor see Image 2 on page 8 If the connecting box is located furthe...

Страница 8: ...arance 1 Recommended location for the connecting box 2 Silumin box recommended in this area 3 This area should be avoided Always use a silumin box In other areas use a heat resisting box T 125 C and h...

Страница 9: ...Absolute measurement must not be exceeded or undershot Middle installation Golv f stkruv Adjustable leg Floor fastener Hearters leg Metal fastener Safety clearances between the bottom of the sauna hea...

Страница 10: ...t N tet Stromnetz Power input N L1 L2 L3 1 2 3 4 5 6 400V 415V 3N Teho Effekt Input Leistung kW L mp vastukset V rmeelement Heating elements Heizeelement 6 8 9 0 10 5 230 V SEPC 199 SEPC 201 SEPC 200...

Страница 11: ...Gr n Green Gr n A4 Kelt Gul Yellow Gelb A5 Harm Gr Grey Grau B1 Rosa Ljusr d Pink Rose B2 Sin Bl Blue Blau B3 Pun R d Red Rot B4 Musta Svart Black Schwarz B5 Violetti Violett Violet Violett Control p...

Страница 12: ...o the grooves in the inside of the heater s vertical beams one end at a time The support for heating elements should stay levelled Position the support between the heating elements Push the pivots at...

Страница 13: ...Product number Product title Rocher 700 Rocher 900 Rocher 1050 1 Mains connector NLWD 1 1 7812550 1 1 1 2 Heating element SEPC 199 2267W 230V 5207770 3 3 Heating element SEPC 201 3000W 230V 5207772 3...

Страница 14: ...tro de reciclaje sin las piedras de sauna ni la cubierta de esteatita Para obtener informaci n acerca del punto de reciclaje p ngase en contacto con la administraci n municipal Instructions for enviro...