![Helo HIMALAYA Elite Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/helo/himalaya-elite/himalaya-elite_quick-instructions_2122367015.webp)
4
Sauna heater safety clearances
Table Safety clearances
Corner and wall installations:
The OLET 31 sensor is installed 40 mm from the ceiling on the centre line of the heater on a
wall. Alternatively, the sensor can be installed on the ceiling above the centre of the heater
– see 'middle installation' for
instructions. The heater must be secured to the floor or the sauna bench structure in order to keep the safety distances the
same.
Middle installation:
If the sauna heater is installed further than 60 mm off a wall or a corner, the installation method is always
middle installation. The heater must be attached to the benches or to a similar structure using a wall support. The OLET 31
sensor is always installed on the ceiling.
Output
Sauna room
Heater minimum clearances
Amount of stones
kW
Volume
Height
From
side to
wall
A
mm
From front to
sauna bench
D
mm
To
ceiling
mm
In kg, approx.
min.
m³
max.
m³
min. mm
6.8
5
9
1900
60
60
870
100
10.5
9
15
1900
60
60
870
100
A
mm
A 330 D
H
mm
Wall support
Heater mounting
point to wall or sau-
na bench
Water tank
Wall support
Heater mounting
point to wall or sau-
na bench
OLET 31
OLET 31
F
870
A A
H
1900
mm
Wall support
Heater mounting
point to wall or sauna
bench
OLET 31 sensor posi-
tion in a ceiling installa-
tion above the heater
within the 330 mm
diameter.
330
Absolute measure,
when the sensor
OLET 31 installed on
the wall.