TMG-1200 Instruction Manual 

 
4. RPM 

Display 

Displays the rpm's of the cold header and cold former in real time. 

 
5. Batch 

counter 

A 3-digit counter which counts the number of times that the preset counter has counted up. 

 
6. Parts 

counter 

An 8-digit preset counter which does not perform counting while detection is off. 

 
7.  Preset counter set point 

Shows the set point of the preset counter. 

 
8.  Trend value sampling display 

Indicates that sampling of Trend data, for absolute value detection, is not complete or 
sampling is being performed. 

 
9.  External timing indicator 

Indicates when the external timing is on. 

 
10. Comment column 

Shows the current fault or operational state. 

 
11. ON/OFF button 

The button to turn on or off fault detection by deviation.  When fault detection is off, “OFF” is 
shown on the set point display. 

 
12.  Batch counter reset button 

Push this button to reset the batch counter to “0”. 

 
13. Sampling button 

Press Sampling button to start sampling Trend data for reference data during operation.  
During sampling, “Sampling” appears on the screen. 

 
14. Adaptive/Trend button 

The button to select whether to cause the deviation display to show the absolute value or 
mean value.  Which of them is selected is indicated by “Adaptive” or “Trend” on the lower 
side of #2 – Set point display.  The button is factory set for mean value display. 

 
15.  Preset counter reset button 

Push this button to reset the preset counter to “0”. 

 
16.  Preset counter select button 

Push this button to set the point of the preset counter (refer to section “Operation of 
Counter”). 

 
17. Setup button 

Push this button to change the set point (refer to section “Changing Preset Range). 

 
18. Setup dial 

Used to change the set point or to change settings in the system mode. 

 
19. Contrast control 

Used to adjust the contrast of the Liquid Crystal Display (LCD) screen.  The contrast control 
is factory adjusted.  Readjust it when the screen is difficult to see. 

Содержание TMG-1200

Страница 1: ...rument Company Inc 361 West Dussel Drive Maumee Ohio 43537 USA 419 893 4356 Fax 419 893 1371 www helminstrument com Non Contact Fault Detector For Cold Heading Machines Force Measurement and Control S...

Страница 2: ...10 Details of Detection 13 Slowdown Detection 13 External Timing 13 Details of System Setting 14 Maintenance Connection of Terminal Block 16 17 Sensor Installation 18 Sensor Adjustment 19 Troubleshoo...

Страница 3: ...mer Sensor Signal Header Former Monitoring by both Absolute value and Mean value Slowdown monitoring Fault Detection Signal Stop Signal This device meets the requirements for the single double and mul...

Страница 4: ...s the monitoring range between the upper and lower limits When the display shows a deviation exceeding the limit values the TMG 1200 displays a fault condition 3 Bar display Displays the deviation fro...

Страница 5: ...h this button to reset the batch counter to 0 13 Sampling button Press Sampling button to start sampling Trend data for reference data during operation During sampling Sampling appears on the screen 1...

Страница 6: ...on to notify of a fault condition Pushing this button cancels the fault condition and causes the red lamp to go off In normal operation pushing this button causes the red lamp to flash and turns off...

Страница 7: ...rts detection after 10 strokes During the initial 10 strokes after the start of the machine fault detection is automatically by passed to prevent erroneous detection due to the initial instability of...

Страница 8: ...to change it and then turn the setup dial To change from mean value adaptive display to Trend absolute value display or vice versa push the Absolute Trend button on the right side of the respective di...

Страница 9: ...of the digit with no black white inversion the position at which setting is turned off 8th digit 7th digit 6th digit 5th digit 4th digit 3rd digit 2nd digit 1st digit setting Off 8th digit The digit p...

Страница 10: ...Sanksu GS 14M Display section Display LCD with back light 128 x 48 pixels Operating temperature range 0 to 50 C Retention temperature range 20 to 60 C Humidity 10 0 RH max wet bulb temperature shall...

Страница 11: ...value sampling is performed can be changed by system setting During sampling Sampling appears on the left side of the screen Mean value comparison is made during sampling After completion of sampling...

Страница 12: ...initial 10 strokes the initial number of bypasses the number of times that detection is turned off can be changed by system setting and begins with the 11th stroke Mean value detection is a detection...

Страница 13: ...hes easily detected The deviation displayed is calculated by the equation Deviation Detected Value Average of 10 Previous Values Ex Detected value 1 823mm Average of 10 previous values 1 820mm 1 823 1...

Страница 14: ...trouble this function stops the machine The rpm when the machine was started in the continuous mode is kept in memory When the rpm becomes lower than that at the start by more than the set value a fau...

Страница 15: ...m repeat steps 1 4 After completing all changes turn the setup dial clockwise to select the end of setting and push the reset button to terminate the system setting mode Symbol TMG appears on the scre...

Страница 16: ...e that each reset button cannot be disabled After completing the change push the reset button to restore the menu screen for system setting Initial value All enabled 8 Setting the reset mode Set the r...

Страница 17: ...er Output Fault Output A Fault Output B Earth Power Blank A1 A2 B1 B2 A1 A2 B1 B2 E S1 S2 Counter Counter Fault Output A Fault Output B Earth 100 240 VAC Output A Output B Kind Contact Power OFF Power...

Страница 18: ...S1 S2 Counter Counter Fault Output A Fault Output B Earth 100 240 VAC Output A Output B Connecting a stop circuit for a conveyor Note If the conveyor has an ON OFF switch make connections at that poin...

Страница 19: ...ocation Page 18 TMG 1200 Instruction Manual HEADING SLIDE FRONT VIEW HEADING SLIDE TOP VIEW FRONT DEAD CETER POSITION MACHINE FRAME HEADING SLIDE FRONT DEAD CENTER POSITION MACHINE FRAME HEADING SLIDE...

Страница 20: ...o 2 0 mm 059 078 1 5 2 0 mm 059 078 4 Place material and operate the machine in the continuous mode Confirm that the bar display shows a value between 1 7 and 2 2mm Placing material causes the FDC pos...

Страница 21: ...chine stops or install a noise filter to the power input section fault output section counter output section external timing input section etc of the device Commands from control When a button is key...

Страница 22: ...8 88 225 6 3 12 79 2 4 5 5mm TMG Monitor ON OFF B C RESET SAMPLING RESET ON OFF SETUP DIAL ADAPTIVE TREND ADAPTIVE TREND P C SELECT P C SELECT CONTRAST SET UP INSTRUMENT CO INC MAUMEE OHIO U S A RIKEN...

Отзывы: