background image

 

i

LIMITED WARRANTY 

 
 

Helm Instrument Co., Inc. (”HELM”) hereby warrants that the instruments and sensors 
(collectively the ”Product”) manufactured by it and sold to customer, are free from 
defects in material and/or workmanship under normal use subject to the following 
conditions. This warranty shall not apply to any Product which has been subjected to 
improper installation, misuse, negligence, accident, alteration, where service has been 
performed by other than an authorized Helm serviceman, or where the serial number 
has been defaced or altered. This warranty shall extend for the one (1) year period from 
date of shipment from our factory or authorized dealer, provided that the product is 
returned, freight prepaid, to Helm within the one (1) year warranty period within specific 
written authorization to perform repairs. Helm’s obligations and the exclusive remedy of 
customer under this warranty are limited to repairing or replacing any defective Product 
at no additional charge and returning Product to customer freight paid. Repair parts and 
replacement Products shall be furnished on an exchange basis and shall be either new 
or reconditioned. All replaced parts and Products shall become the property of Helm.  
 
EXCEPT AS SPECIFICALLY STATED HEREIN, HELM MAKES NO WARRANTIES 
EXPRESSED OF IMPLIED, OF THIS PRODUCT INCLUDING BUT NO LIMITED TO 
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR 
PURPOSE, OR AS TO THE QUALITY, UTILITY OR PERFORMANCE, ALL QF WHICH 
ARE HEREBY EXPRESSLY EXCLUDED. IN NO EVENT SHALL THE LIABILITY OF 
HELM EXCEED THE PURCHASE PRICE OF THIS PRODUCT. NOR SHALL HELM BE 
LIABLE FOR ANY DAMAGES WHATSOEVER, INCLUDING BUT NOT LIMITED TO 
SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL CHARGES, EXPENSE OR 
DAMAGES, ARISING OUT OF THE USE OR INABILITY TO USE THIS PRODUCT OR 
FOR ANY CLAIM BY ANY OTHER PARTY.  
 
Should you have any questions concerning this Warranty, you may contact Helm by 
writing or calling:  
 

HELM INSTRUMENT COMPANY, INC. 

CUSTOMER SERVICE 

361 WEST DUSSEL DRIVE 

MAUMEE, OHIO 43537 

(419) 893-4356

 

 
 

Содержание PTM-1100 Series

Страница 1: ...1 HELM INSTRUMENT CO INC PTM 1100 USER MANUAL REV 1 JUNE 2010 Helm Instrument Company Inc 361 West Dussel Drive Maumee Ohio 43537 USA 419 893 4356 Fax 419 893 1371 www helminstrument com...

Страница 2: ...ring or replacing any defective Product at no additional charge and returning Product to customer freight paid Repair parts and replacement Products shall be furnished on an exchange basis and shall b...

Страница 3: ...IONS 3 CUSTOMER SUPPLIED POWER 3 CAM INPUT 3 HIGH LOW CAPACITY FAULT RELAY OUTPUT 3 STRAIN GAGE INPUT 3 TOUCH SCREEN INTERFACE 4 MAIN MENU 4 SETUP SCREEN 5 JOB RECIPE SCREEN 6 PTM MODULE 7 STRAIN GAGE...

Страница 4: ...MODULE PTM is a single channel strain gage sensor input module to process the signal of the strain gage to analog output PTM provides Auto Zero feature patented by Helm Instrument Co Inc The Auto Zero...

Страница 5: ...ded 24VDC and DC common or Use the supplied DC1 24VDC through a dry contact to A1 and connect DC2 0VDC to A2 This input can be triggered with a proximity switch or a PLC output This input is the look...

Страница 6: ...t Low Capacity Alarm Set point Pilot is set when there is a Low tonnage alarm Pilot can be set and relay is off if in calibrate mode SPM Displays the current Strokes Per Minute which is calculated bas...

Страница 7: ...capacity of the press HIGH TONNAGE Displays the current High Capacity Alarm Set point Pilot is set when there is a High tonnage alarm Pilot can be set and relay is off if in calibrate mode LOW TONNAG...

Страница 8: ...e the desired recipe 1 20 UP ARROW Used to move to higher value recipe DOWN ARROW Used to move to lower value recipe HIGH TONNAGE Press to set the recipe High Capacity Alarm Set point LOW TONNAGE Pres...

Страница 9: ...the module to the center Off position cycle the press and record developed tonnage 2 Adjust the gain pot CW and cycle the press again 3 Compare the Peak Output scaled value on the display meter to the...

Страница 10: ...the Peak Capture for the new machine cycle Normal Operation After the set up and calibration have been completed the 3 position calibration toggle switch should be set to the lower A Z Auto Zero posi...

Страница 11: ...PTM 1100 Operators Manual 9 PTM MODULE DRAWING...

Страница 12: ...PTM 1100 Operators Manual 10 PTM MODULE WIRING...

Страница 13: ...PTM 1100 Operators Manual 11 PTM MODULE SIGNAL DIAGRAM...

Страница 14: ...PTM 1100 Operators Manual 12 PTM 1100 USER CONNECTIONS...

Отзывы: