background image

Installation Instructions and Instructions for Use 

 

 

Subject to technical modifications – Date of Issue May/2020 

7

Connection diagram 

 

  

1

2

3

4

5

2

0

 

Fig. 1 

  

 

  

Legend 

1

  Phase L 

2

 

Neutral conductor N 

3

  Junction box 

4

 

Right angle 

5

  ONYX.WEATHER 

  

 

  

Mains cable for mains voltage 230 V AC / 50 Hz 

The 5 m long mains cable is provided for the voltage supply of the module. Phase and 
neutral conductor are colour-coded (blue = neutral conductor; brown = phase). 

  

Installation Instructions and Instructions for Use 

 

Subject to technical modifications – Date of Issue May/2020 

Installation to the facade 

 

  

 

For the installation of the ONYX.WEATHER the pluggable bottom part of the 
housing is removed. This can easily removed by pulling it downward. The 
space between the boreholes for the screwing is 20 mm (see Fi. 1). 

  

 

  

 

Brickwork / concrete

 

For the installation of ONYX.WEATHER in the brickwork or on concrete the 
anchors and screws included in the scope of delivery must be used. For this 
purpose, a borehole with a diameter of 8 mm, min. 40 mm deep, must be 
provided. 

  

 

  

 

Wood

 

For the installation of ONYX.WEATHER on a wooden facade, the enclosed 
screws or other suitable woodscrews can be used. 

  

 

  

 

Thermal insulation composite system

 

For the installation of ONYX.WEATHER on the thermal insulation composite 
system special insulation dowels must be used. For detailed installation 
instructions of these insulation dowels, please refer to the instructions of the 
dowel manufacturer. 

  

Installation Instructions and Instructions for Use 

 

 

Subject to technical modifications – Date of Issue May/2020 

9

Configuration 

 

  

 

Before configuring the ONYX.WEATHER, download HELLA’s free app ON-
YX

®

 from the app store / Google Play to your smart phone. 

 

Before you can use ONYX.WEATHER in combination with ONYX.CENTER, 
ONYX.WEATHER must be added to the app ONYX

®

. You will find all infor-

mation regarding the configuration in the instructions for ONYX.CENTER / 
ONYX.CLICK, directly in the app ONYX

®

 or in the download area on our 

homepage https://www.hella.info. 

 

The serial number (ID) to assign multiple ONYX:WEATHER can be 
found in the housing of the weather sensor (pull the pluggable bottom 
part of the housing downwards). 

  

 

  

 

Setting the wind resistance class for your products. 

The wind resistance class can be individually set for every product that is 
monitored by the ONYX.WEATHER. The wind resistance class depends on 
the sun protection product itself as well as on the type of installation. After 
adding the weather sensor, all assigned products are configured with stand-
ard wind resistance classes. These wind resistance classes must then be 
adapted individually to the wind resistance classes of your sun protection 
product. The information about the wind resistance class of your product can 
be found in the technical documentation of your sun protection product. 

  

Installation Instructions and Instructions for Use 

 

10 

Subject to technical modifications – Date of Issue May/2020 

Configuration 

Wind Protection Classes 

  

Wind pro-

tection 

class 

Wind 

force (de-

grees acc. 

to Beau-

fort) 

Description 

Wind speed* 

m/s (km/h) 

Effect of the wind in 

the interior land 

0

 

0-3

 

Calm - light 

breeze 

0-

5.4

 (0-

19

Smoke raises vertically, 

wind moves thin twigs 

1

 

4

 

moderate 

breeze, 

moderate 

wind 

Wind speed 
(Beaufort 
number) 

5.5-

7.9

 (20-

28

Wind moves twigs and 

thin branches, whirls up 

dust and loose paper 

2

 

5

 

fresh 

breeze, 

fresh wind 

8-

10.7

 (29-

38

small deciduous trees 

begin to sway 

3

 

6

 

strong wind 

10.8-

13.8

 (39-

39

strong branches are 

swaying, umbrellas can 

be held with difficulties 

only 

4

 

7

 

near gale 

13.9-

17.1

 (50-

61

Resistance felt when 

walking against the 

wind, whole trees in 

motion 

5

 

8

 

stormy wind 

17.2-

20.7

 (62-

74

Branches break off from 

the trees, walking out-

side is difficult 

6

 

9

 

storm 

20.8-

24.4

 (75-

88

Branches break off from 

trees, smaller damage 

on houses 

Source: ift Rosenheim

 

  

* ... In the respectively selected wind resistance class, ONYX:WEATHER always gives a 
wind alarm at the upper limit value (marked in bold). 

  