1. OvErvIEW
1.0.0. Safety Guidelines
This control conforms to the National Electric Code and is
certified by the Underwriters Laboratory.
Any electrical wiring
or modifications to the control I/O should be performed with the
power disconnected. Service should only be performed by a
qualified professional.
Carefully review all instructions in this manual for installation
and use. Do not modify equipment under any circumstances;
use only as designed. Install all components in an accessible
location for servicing and maintenance. Noncompliance with
these guidelines will void all warranties.
Follow all local building codes and regulations, as well as these
industry accepted guidelines and standards:
BUILDING
USEC, UBC, UPC, NRCA
ASHrAE
Solar Energy Equipment
NFPA 70
National Electric Code
1.0.1. Introduction
The Delta-T Pro controller is designed to control solar thermal
collector systems for use in domestic water, heating and
commercial systems. This control is not suitable for solar pool
heating systems.
Each control contains the user interface software which can
be accessed via an internet capable device and web browser.
When the device is connected to an internet capable network,
the controller can transmit data to the Heliodyne monitoring
site for detailed data logging and system tracking. For best
results, Heliodyne recommends consulting an IT professional for
connecting to the device and configuring network parameters.
An intermediate level of knowledge in IT is required to install this
controller.
The Pro Controllers contain battery-backed SRAM, protecting
the system clock, settings and data in case of a power outage.
Because the battery is only lightly used during these events, it is
not user serviceable and will last the life of the control.
1.0.2. Models
The Delta-T Pro controller is available with either an Ethernet
connection
or
a Wi-Fi signal.
•
DLTA 000 001 [Ethernet]
•
DLTA 000 002 [Wi-Fi 802.11 b/g]
1.0.3. computing requirements
•
PC, Mac, PDA or other internet capable device
•
Web Browser with JavaScript enabled
•
Ad-hoc network capable
1.0.4. Network requirements for Monitoring communication
•
Always on internet connection (DSL, cable, T1, etc.)
•
DHCP enabled network or available static IP-Address for
controller
•
Network must allow TCP communication on port 9999
•
[Wi-Fi] 802.11b/g compatible router with Open, WPA -
TKIP, or WPA2 - CCMP (aka AES) encryption
•
Personal WPA will work but enterprise WPA will not
!WeP oR oTHeR WPa/WPa2 enCRYPTIon alGoRITHMs aRe noT sUPPoRTeD!
1.0. For service, contact Heliodyne: (888)878-750