INSTALLATION INSTRUCTIONS

•  Before  you  start  installing  the  solar 

water  heater,  please  read  carefully  all 

the  installation  instructions  stated  and 

illustrated in this manual.

•  Before the installation of the solar water 

heater, it is very important that customer 

and  installer  agree  on  all  the  details 

concerning the correct and safe instal

-

lation  of  the  appliance,  such  as  loca

-

tion,  placement  point,  static  resistance 

and control of the surface on which the 

appliance  will  be  placed,  piping  and 

wiring run etc.

•  The  position  you  will  choose  for  the 

installation  of  the  solar  water  heater, 

should not be shaded by any obstacles 

(trees,  buildings…  etc)  all  around  the 

year.

•  The  installation  should  be  done 

according to the electric and plum

-

bing  regulations  applicable  in 

your area.

•  For  optimum  perfor

-

mance, the solar water 

heater  must  face  the 

south

,  for  countries 

located  in  the  Northern  hemis

-

phere  and 

north

  for  countries 

located in the Southern hemisphere. In 

case that it is not totally possible for the 

solar  water  heater  to  face  the  equator, 

you  can  turn  it  towards  East  up  to  30

o

 

if  major  hot  water  draw  is  before  2pm, 

or  towards  West  up  to  30

o

  if  major  hot 

water draw is after 2 pm. In both cases, 

the  losses  of  the  total  annual  solar 

contribution, is no more than 6%.

•  If  the  solar  water  heater  must  be  ins

-

talled on a roof where the inclination is 

less than 15

o

 or more than 32

o

, then a 

different  than  the  standard  equipment 

of  the  support  base  must  be  used, 

similar to the one used for regions with 

typhoons, hurricanes and heavy winds.

•  For  the  safer  installation  of  the  solar 

water heater on sloping roofs, it is neces

-

sary to install the support base in such a 

position  so  that  the  storage  tank  to  be 

placed exactly over a roof timber and in 

no case way between two timbers.

•  If the surface on which the solar water 

heater will be installed (sloping or flat) is 

not compatible with the standard equip

-

ment supplied with each appliance, then 

a  different  equipment  must  be  used. 

The  installer  has  to  choose,  propose 

and  install  this  different  equipment, 

always under the concurrent opinion of 

the customer.

•  For installation on a sloping roof, the “D” 

plates must be screwed with the appro

-

priate screws and nuts on the roof tim

-

ber, in order to secure the right and safe 

installation of the solar water heater.

•  In  regions  subject  to  heavy  snowfalls, 

it  is  very  important  to  ensure,  that  too 

much snow doesn’t accumulate behind 

the  storage  tank,  and  to  check  if  the 

supports of the standard equipment are 

good enough to withstand the weight of 

the expected snow. The same attention 

must  be  paid,  for  regions  with  heavy 

winds  and  storms.  In  these  cases,  the 

storage tank must be placed in a stable 

way on the roof and must be tightened 

with  the  additional  metal  straps.  It  is 

absolutely necessary to use the typhoon 

set (page 22).

•  The tubes of the solar water heater as 

well  as  the  cold/hot  water  piping  must 

be very well insulated.

•  Special attention must be taken for the 

filling and connection of the closed cir

-

cuit.  Only  experienced  technicians  can 

provide you with the connection and the 

filling.  Before  filling  the  closed  circuit 

with thermal fluid, the storage tank must 

be completely filled with water.

•  Before  starting  the  installation  of  the 

solar water heater, you must read care

-

fully  all  the  instructions,  described  and 

illustrated in this manual. 

•  After  you  have  finished  the  installation 

clean the area where all the work took 

place.  Fill  in  the  warranty  with  all  the 

required details and have customer sign 

it. Advice customer to mail immediately 

the coupon of the warranty to  Helioakmi 

S.A.

•  The  installation  must  comply  with  the 

local and national regulations and lows 

(plumbing,  electricity,  hygiene,  urban 

and  others)  that  are  into  force  in  your 

country. 

•  The  observance  of  the  instructions 

stated on this manual is very important 

and the non-observance may cancel the 

validity of the warranty.  

•  Helioakmi  S.A.  declines  any  responsi

-

bility of any kind, that may arise from a 

defected installation or from an incorrect 

manipulation or from   any elements or 

accessories that are integrated/fitted on 

the appliance.

Содержание NovaSun 200

Страница 1: ...TECHNICAL MANUAL INSTALLATION MAINTENANCE AND USE INSTRUCTIONS ENGLISH ...

Страница 2: ...limatic conditions and for all types of water qualities A philosophy that leads the way and makes us as professionals feel the weight of responsibility and obligation to offer products and services that are in harmony with the environment and man To hand over a better world to our children Always true to our principle for excellence in design and continuous advance ments HELIOAKMI today offers hig...

Страница 3: ...AGE TANK AND COLLECTOR ON THE SUPPORT BASE Page 14 CONNECTION INSTRUCTIONS OF THE STORAGE TANK COLLECTOR AND COMPONENTS Page 16 FILLING INSTRUCTIONS OF THE CLOSED CIRCUIT WITH THERMAL FLUID Page 18 DESCRIPTION OF THE PARTS OF THE ELECTRIC RESISTANCE AND THERMOSTAT CONNECTION INSTRUCTIONS Page 20 SPECIAL CLIMATIC CONDITIONS Page 22 INSTRUCTIONS AFTER THE INSTALLATION Page 24 TROUBLESHOOTING REPLACE...

Страница 4: ...s material low carbon steel 1 5 mm Cylinder s internal Protection durosmalt 80 120 microns Additional protection magnesium rod Electric resistance copper Thermostat bipolar of four contacts Power rate available from 0 8kW 4kW TECHNICAL SPECIFICATIONS OF THE STORAGE TANK EXTERNAL DIMENSIONS ALL MODELS Collector with titanium selective treat ment TECHNICAL SPECIFICATIONS OF THE COLLECTOR 1 External ...

Страница 5: ... on the outside The collector is packed with 4 plastic protective elbows atta ched on each corner which are fast tightened around the collector with a plastic strap upon special order the collectors could be delivered in groups of 10 pcs on a wooden pallete All the parts of the support base the plastic bag with the connection fittings the thermal fluid and other accessories are packed in a carton ...

Страница 6: ...ater which will fulfil your needs For a better choice of the appliance the local climate conditions must be taken into a serious consideration as well as your needs for hot water The energy saving that you will have with the NOVASUN solar water heater depends on the use of hot water the use of the electric resistance and the local weather conditions Under fa vou rable weather conditions the energy...

Страница 7: ...t equipment must be used The installer has to choose propose and install this different equipment always under the concurrent opinion of the customer For installation on a sloping roof the D plates must be screwed with the appro priate screws and nuts on the roof tim ber in order to secure the right and safe installation of the solar water heater In regions subject to heavy snowfalls it is very im...

Страница 8: ...8 A U U D D C E Z Z B B F F C Support base for 200 260 300 with 2 collectors Assembly diagram of the support base on a flat surface ...

Страница 9: ...by any obstacle trees buildings etc see obstacle diagram page 10 The same support base is used for either sloping or flat sur faces Connect the plates A B C D U and Z by screwing them tight as shown in the drawings For models 260 and 300 screw also the plates F Screw gently the bottom plate E on the plates B attention The top plate E is adjusted after the placement of the collectors Plumb the supp...

Страница 10: ...its installation on a tiled rood two additional plates E 840mm length are required These additional plates replace the plates C 1150mm length Alternatively for the formation of the parallelogram frame you can use the existing plates E 840mm length in the place of the plates C The plates C 1150mm by making two holes 10 where required will be installed in the place of the plates E 10 ...

Страница 11: ...tes B are tightly screwed on the holes of the plate A Screw gently the bottom plate E on the plates B attention The top plate E is fixed after the place ment of the collector s note The standard support base can be used also for surfaces with minimum inclination 15o and maximum 32o For smaller or greater inclinations diffe rent equipment is offered OBSTACLE TABLE Latitude Distance between collecto...

Страница 12: ... Thermal fluid outlet pipe from the collector to the storage tank 11 Collector s 12 Pipe unions collector connectors Only for models with two collectors 13 Bottom left hand collector pipe 13A Plug 1 2 14 Filling pipe for the closed circuit 14A Plug 1 2 15 Cold water inlet pipe indication cold inlet 15A Reducer 3 4 1 2 16 Thermal fluid outlet pipe from the storage tank to the collec tor Indication ...

Страница 13: ...13 01A 01B 20A 14A 17A 14 15A 15 16 17 12 19 03 07 07 18 20 18 20 17 17A 15A 15 18 03 03 ...

Страница 14: ...and centralize the collector s on the support base For the models 200 260 and 300 which consist of two collectors you must connect them to each other by using the pipe unions 12 supplied with each appliance Secure the bottom part of the collector s by screwing tightly the bottom plate E on the plates B Screw tightly the top plate E on the plates B securing the collector s E E Z 20A B E A 12 B Inst...

Страница 15: ... on the two U check carefully if the plates U and Z are screwed tightly to the plates B b The electric resistance must be on the right hand side as we face the appliance c Ensure that the appliance does not tilt from one or the other side and that the tubes 02 and 14 of the storage tank are vertical on the highest point of the storage tank Use necesserily a plumb Z B E U 20A U ...

Страница 16: ...ch is located on the bot tom left hand side of the collector and use Teflon or oakum for their complete water tightness For models 200 260 and 300 which have two collectors connect them by using the collector connector pipe unions 12 supplied with each applian ce 17 17A 13A 12 Connection instructions of the storage tank collector and ...

Страница 17: ...lve type 15BC use the appropriate for each case procedure Connect the cold water supply to the spherical switch and turn the cold water supply on until the storage tank is com pletely filled When you are filling the storage tank with water the outlet of hot water 08 should be opened Connect the hot water supply to the storage tank outlet pipe 08 Indication hot outlet After connecting all the fitti...

Страница 18: ...case of Helioakmi S A The use of water only or other liquid may cancel the validity of the warranty 20 Place the protective side cover 20 12 Add some more fluid in the closed circuit until it overflows from the tubes 14 and 02 Screw the plug 14A onto the tube 14 and fix the safety valve 02A onto the tube 02 Check carefully all connections for com plete water tightness 14 02A 14A 02 17A After the f...

Страница 19: ... 200E x 4 20m2 18 lt 16 lt 2 lt 14 5 lt 3 5 lt 12 5 lt 5 5 lt 12 lt 6 lt 10 5 lt 7 5 lt 9 lt 9 lt NOVASUN 260 x 4 20m2 21 lt 19 lt 2 lt 16 5 lt 4 5 lt 14 5 lt 6 5 lt 14 lt 7 lt 12 5 lt 8 5 lt 10 5lt 10 5 lt NOVASUN 300 x 4 20m2 22 lt 19 5 lt 2 5 lt 17 5 lt 4 5 lt 15 5 lt 6 5 lt 14 5 lt 7 5 lt 13 lt 9 lt 11 lt 11 lt NOVASUN 300E x 5m2 23 lt 20 5 lt 2 5 lt 18 5 lt 4 5 lt 16 lt 7 lt 15 5 lt 7 5 lt 13...

Страница 20: ...switch indication F or S CONNECTION OF THE CABLES 1 Turn off the power main supply 2 The cover of the electric resistance is on the right hand side of the storage tank Unscrew the two screws and remove the cover 3 The thermostat is adjusted from the factory at 60o C You can adjust it at the temperature you wish by using the temperature control 34 In that case we advise that the temperature you wil...

Страница 21: ...order the electric resistance can be offered with power from 800W to 4000W For power of 110V the electric resis tance is available upon special order with power from 800W to 2000W note A certified electrician must make all the electric connections Ensure that all the electric connections comply with the electric regulations applicable in your area and your buil ding Do not turn on the electric res...

Страница 22: ... be good enough for the safe installation of the appliance Special climatic conditions To assemble the support base follow the same assembly procedures mentioned on pages 9 10 and 11 12 for flat or sloping surfaces For the connection of the plates U Z and B use the long screws small step nuts Before you adjust the metal belts around the storage tank place the rubber profile between the storage tan...

Страница 23: ...port base carton For the safer installation of your applian ce we recommend you to secure the storage tank on the support base using more mettal belts than the ones illustra ted in the photos All the parts and accessories of the typhoon set are packaged in one car ton which carries on the outside the description TYPHOON SET For installation on a sloping roof we recommend you to use more metal belt...

Страница 24: ...er heater continues not to supply hot water contact your local distributor B IF THE SOLAR WATER HEATER DOESN T SUPPLY HOT WATER WITH THE ELECTRIC RESISTANCE 1 Turn off the power supply and remove the resistance s cover 2 Check the safety thermal switch F on the thermostat which has to be pushed in 3 Check the wiring between the thermo stat and the electric resistance 4 Check if the thermostat is a...

Страница 25: ... installation of maximum five appliances In multiple connections where the electric resistance is used you should avoid connec ting the electric resistance in the storage tanks of the first two appliances These appliances will be used to pre heat the water for the consumption For this kind of installation or for more than three solar water heaters connected in a row you have to make a special requ...

Страница 26: ... of tube curves etc 2 Pressure drop p must be almost the same in hot and cold water tubes TYPICAL INSTALLATION OF MULTIPLE UNITS notes 1 All the branch lines to the storage tanks must have same length and geo metry diameter of tube curves etc 2 Pressure drop p must be almost the same in hot and cold water tubes 3 In case that you have to install one more solar water heater the diameter of the pipi...

Страница 27: ...es 1 All the piping in 20 mm diameter For this kind of installation or for more than three solar water heaters connected in a row you have to make a special request for 3 4 inlets outlets pipes on the storage tank 2 We recommend you to use a maxi mum of five appliances in a row COLD WATER INLET HOT WATER OUTLET ...

Страница 28: ...ece Tel 30 210 5595 624 210 5595 625 210 5595 626 Fax 30 210 5595723 web site www helioakmi gr e mail megasun helioakmi gr NOTE HELIOAKMI S A reserves the right to change any specifications of the product and their accessories without prior notice 0709 ...

Отзывы: