5. Installation/Commissioning
This product may only be installed by a qualified specialist electrician.
Before the installation is done, the connection lines to the building must be disconnected from the power
supply and protected against being switch on accidently. Take the appropriate automatic circuit breakers
out of the junction box in the building.
Make sure that the foundation is suitable to support the weight of the LED-Panel, permanently and
reliably.
Saw out the installation dimensions at the desired site. Use the permanently assembled holding clips to
fasten the LED panels. Make sure that no connections are damaged.
Now wire up the connection lines of the building installation at the screw terminals of the light. The brown
(or black) cable is usually the phase conductor. Connect this to the terminal marked with an "L". The blue
conductor must be connected to the terminal marked with an "N".
Do not bend the cable; make sure that the cable and the plug are free from any tractive and torsional
forces. Protect all cables and insulations from any possible damage.
Check the proper connections once again.
Switch on the circuit breakers of the junction box in the building once again.
6. Functional faults
The LED panel does not switch on
Is the switch of the LED panel on the wall turned on?
Is the transformer correctly assembled and connected?
Check the connected lines
7. Technical data
Article
Connection
LED-Panel
Protection
class
Protection
class
27782
Ø 130mm, Installation
dimensions Ø 85mm,
3 + 8W (max.11W), 400lm, 4000K
IP 20
III
Trans-
former
200-240 V
AC, 50 ~ 60 Hz,
Output 1: 9-12 V DC
Output 2: 30-44 V DC
IP 20
II
27783
Ø 180mm, Installation
dimensions Ø 135 mm,
5 + 15W (max. 20W), 1300lm, 4000K
IP 20
III
Trans-
former
200-240 V
AC, 50 ~ 60 Hz,
Output 1: 9-12 V DC
Output 2: 30-44 V DC
IP 20
II