4 Operation
CPM 500 Electronic Peak Pressure Indicator
12
4.8 Measuring with CPM 500
Charge battery
Charging time: min. 2 hours
Start measurements on the engine
2-and 4 stroke application
Open indicator cock and close. Install sensor with adaptor at cylinder no.1 and open indicator cock
Press “
On
” at CPM 500
Press
“Measure”
and wait about 5-10 s
Fig.11: Indication during measurement on cylinder
Fig.12: Indication (1-2 s) of measured values from cylinder
After indication of measured cylinder values (1-2s) the display switches automatically to next cylinder.
Repeat measuring procedure for all remaining cylinders!
For to change engine mode 2- or 4-stroke press “2/4” to select application on a 2- or 4 stroke engine
Remark: The CPM 500 has a overheating protection of measuring cell for temperature > 300°C
Remark: The CPM 500 turns off automatically after 2 minutes without pressing any push button!