www.heinner.com 1300W, 50-60Hz, 220-240V
52
After power on, the motor will not run, after a
few seconds, the display will show "Warning
Brew Group Block". It is because the brewing
motor is malfunction, during normal operation.
Send to the service center for
changing the brewing motor.
4
Warning
Miss Dregs Box
It prompts the brew group is not placed in
place or missing.
Only the brew group is placed
in
place
completely,
the
appliance will operate
;
It prompts the water tank is lack of water, the
buoy is not on the best state.
Fill the water tank with water.
;
The water quantity exceeds 250ml. The buoy is
blocked on the bottom of slip groove. Have
foreign objects.
5
Warning
Fill Water tank
Check the buoy whether is floating
The coffee maker will operate
normally after removing out the
foreign objects.
The water quantity exceeds 250ml,the buoy is
floating more agility.
Send to the service center for
changing the sensing switch
6
Please
Turn off knob
It prompts the steam control knob has been
turned on.
Turn the steam control knob to
the“ 0 ” position.
7
Warning
No Sensor
If the environment temperature is below 0
degree, it will “no sensor” displayed after start
the appliance.
Place the coffee machine in the
environment of 25° for 10-20
minutes,
it
will
operate
normally; If it can not work
normally after 20 min, please
send the coffee maker to
service center.