www.heinner.com 1300W, 50-60Hz, 220-240V
51
NO. ABNORMAL
DISPLAYS
AND
SYMPTOMS
WORKING STATES AND CAUSES
REPAIR AND CORRECTIONS
1
Warning
Door open
It prompts that the door is not closed well
Close the door, and
the
appliance will begin to work
2
Warning
Miss Brew Group
It prompts that the brew group is not placed in
place or is missing.
Position
the
brew
group
properly, and the coffee maker
will return to normal state.
The user open the side door and draw out the
brew group by mistake when the brew group is
running, at the time, the water inlet of brew
group has connected with brewing outlet, the
brew group cannot be removed out.
1. Unplug the power outlet;
2.Turn the brew group handle
to make the clip of brew group
on the original state, press the
brew group bracket with a little
force, make the brew group is
connected
with
the
transmission
shaft
of
reducer, and close the brewing
switch( if the brewing switch
cannot be closed, please send
the machine to the service
center for
repairing)
3.Operate according to the
section of START APPLIANCE,
the coffee machine will operate
normally.
3
Warning
Brew Group
Block
After power on, and the motor is running, but
after a few seconds, the display is showing
"Warning Brew Group Block". It means that the
journey switch is malfunction, during normal
operation.
Send to the service center for
repairing and changing the
journey switch.