$8?EPDFÏÏV
Page
13
/
43
44. Setup Procedure
For better understanding the following sections 4.1 and 4.2 explain settings for the display only.
Model-specific settings for Analogue Output, Preselections and Serial Link will be explained
separately, later.
4.1. Basic Parameters
The subsequent settings are of unique nature and must only be made upon the very first setup.
The basic setup selects the desired operation mode of the unit, the input characteristics
PNP/NPN and the desired brightness of the LED display.
Menu
Setting Range
Default
SSI-
-
Mode
Setting of Master Mode or Slave Mode
For details see section 5.1
SSI-
-
Bits
Bit length of the SSI string
For more details see section 5.2
.....
SSI-
-
Format:
Setting of the SSI code (Binary or Gray)
SSI-
-
Baud Rate
0.1 ... 1000.9
kHz
100.0
k
k
Hz
SSI Test
SSI Self test functions (see 5.5.)
etc.
Characteristics *)
Switching characteristics of the Reset input
NPN: switch to "-" *)
PNP: switch to "+"
Brightness
20%, 40%, 60%
80% and 100%
100%
Brightness of the 7-segment LED display
*) Please observe hints given in chapter 1.3