11

Room temperature is distinctly above the set temperature

Possible causes

Remedies/comments

– 

The thermostatic valve does not capture – Take care that the thermostatic valve
the room temperature but is influenced

will be exposed to the circulating air 

by colder air, e.g. draught

of the room without any obstacle

– External heat influences could cause an  – Thermostatic valves utilize the external

increase of the room temperature alt-

heat supplied free of charge for room

hough the thermostatic valve did shut

heating and, thus save energy

off the supply of hot water to the 
radiator

Noise in the thermostatic valve

Possible causes

Remedies/comments

– 

Excess differential pressure

– Arrange for reduction of pump pressure or

have the hot water distribution checked

– Air in the heating system

– Vent the heating system, refill water

– Wrong flow direction passes through

– Arrange for the flow direction to be 

the radiator

corrected or have a corresponding valve
installed

Room temperature is distinctly below the set temperature

Possible causes

Remedies/comments

– 

The thermostatic valve with incorpo-

– Take care that the thermostatic valve

rated sensor is covered with curtains, 

will be exposed to the circulating air of 

radiator covers or panelling etc.

the room without any obstacle or have 
a remote sensor or remote dial installed

– The thermostatic valve with incorpora-

– Arrange for installation of a remote  

ted sensor is mounted in vertical position

sensor or remote dial

– The nominal performance of the radiator – Have the heating curve or the radiator

is insufficient in relation to the size of the

performance adapted

room

– The heating system does not supply  

– Arrange for checking of heating curve, 

sufficient energy

circulation pump, time programme, 

heat generator, etc.

Содержание Thermolux K

Страница 1: ...Thermostatic valves Thermolux K Consumer information Please keep this brochure in a safe place To be precise...

Страница 2: ...ting aid for visually handicapped persons Economy clips 8 Marking of a temperature setting Uper marking of a temperature range Lower marking of a temperature range Limiting of a temperature setting Up...

Страница 3: ...ting Front side tempe rature setting aid favourable in case of a bad vision on the index figures Left marking ca 16 C and right marking app 24 C Basic setting app 20 C Perceptible marking for visually...

Страница 4: ...gs be blocked respectively Heimeier Thermolux K thermostatic valves consist of the thermostatic head and the thermostatic valve body If temperature rises e g due to insolation electric appliances or p...

Страница 5: ...individual temperature setting or to limit the temperature set ting range internally i e unchangeable from outside either to a higher or to a lower temperature level of your ther mostatic valves Inte...

Страница 6: ...iator covers or panelling etc or be fitted in narrow alcoves or even be mounted in vertical position as in such cases no precise temperature control will be possible Otherwise a remote sensor or remot...

Страница 7: ...le heating systems are usually so designed that excessive temperatures Index figures 4 and 5 will not be reached in most cases This the more so is applicable to weather controlled supply temperatu res...

Страница 8: ...All rooms at night reduced heating performance Staircase porch Cellar rooms anti frost protection setting Kitchen hall 28 C 24 C 22 C 20 C 18 C 16 C 14 C 12 C 6 C Should higher temperatures be requir...

Страница 9: ...he desired tempera ture setting position or when the red economy clip will be used as a limi tation to this limit stop Even during a longer absence a temperature re duction is advised to be effected A...

Страница 10: ...ove the economy clip please see fig 2 Thus the thermostatic head can be turned and set to the desired temperature e g index figure 3 20 C Thereafter the red eco nomy clip must be inserted in the groov...

Страница 11: ...Temperature Setting Upper limiting of the temperature range In this case the red economy clip must be pulled back up to the stop please see fig 1 lift and remove it please see fig 2 Then the ther most...

Страница 12: ...lation to be short but intensive tilation tilted window position and low outside temperatures the room tem perature drops below the lowest tempe rature setting on the thermostatic valve Valve seat is...

Страница 13: ...system Vent the heating system refill water Wrong flow direction passes through Arrange for the flow direction to be the radiator corrected or have a corresponding valve installed Room temperature is...

Страница 14: ...re sensing liquid is situated in the remote sensor contrary to the Thermolux K with built in sensor and actuates from there via the capillary tube the corrugated tube in the ther mostatic head But oth...

Страница 15: ...o buttons which are used to carry out individual time programming practically in pas sing In this case a simple push of the button replaces the typical situation of turning the thermostatic valve down...

Страница 16: ...appliances people staying in the room etc This external heat has an influence on the room temperature and in turn on the thermostatic valve please see page 2 Should the so generated heat in the room...

Страница 17: ...aintenance 3 Marking 8 Moon symbol 6 7 Mounting instructions 4 5 Night performance reduced 3 6 7 Noises 11 Office 6 Panelling 13 Porch 6 Pump 10 11 Radiator cover 4 Radiator panelling 4 Reduced perfor...

Страница 18: ...9592 Erwitte Germany Telephone 49 2943 891 0 Fax 49 2943 891 100 www heimeier com Consumer brochure A5 Printed on paper bleached without the use of chlorine 6080 18 480 06 06 Subject to technical alte...

Отзывы: