background image

20

There are possible risks to bear in mind when operating you

solid fuel stove, regardless of the brand.

These risks can be minimised if you follow the instructions and

recommendations in this manual.

Below is a list of rules and advice but above all you should use

your common sense.

1.  Keep all inflammable materials (furniture, curtains, clothing

etc) at least 0.90 m from the stove.

2.  Ashes should be removed from the stove in a metal con-

tainer and taken outside the house immediately.

3.  Liquid fuel should never be used to light your stove.

Keep any inflammable liquid (oil, petrol, alcohol etc.) far away

from your stove.

4.  Inspect your chimney regularly and clean it when neces-

sary.

5.  Do not situate it near inflammable walls or walls which ha-

ve any type of covering which could be damaged by high tempe-
ratures (varnish, paint etc.)

8. SAFETY

9. TECHNICAL SPECIFICATIONS

Fig. 20

Model

Measurements (mm)

C-4/70

Stove measurements (mm)

Height

370

560

370

105

450

467

630

600

700

A

B

C

D

E

Diamet er 175

200x200

5-6

10.900

Width

Depth

Kg

Plate piping

(mm)

Works pipe

(mm)

Height *

(m)

Kcal/h

Weight

Chimney measurements

Power

Ventilator motor:  Tension 220 V. Power 2x13 W.

Draught = 2 mmca

* For other heights contact the Distributor or Manufacturer.

Heat resistant paint

, for cast iron pieces and plate.

Refractory paste

, for water tightness and seals.

Anti-soot

, a powerful catalyser to eliminate unburnt particles.

Fire lighters

, for a rapid and clean fire.

Window cleaner

, the perfect product to eliminate carbonised

grease from the glass of stoves, fire places etc.

10. MAINTENANCE PRODUCTS

C

D

E

A

B

Содержание Compact C-4

Страница 1: ...y directly INDUSTRIAS HERGÓM S A does not take any responsibility whatsoever for the dama ges caused by or resulting from alterations to its products that have not been authorised in wri ting or for defective installations Furthermore it reserves the right to modify its finished products without prior war ning Industrias Hergom S A with registered offices in Soto de la Marina Cantabria Spain of fe...

Страница 2: ...H THE CANOPY B AND OR TO OTHER ADJACENT ROOMS Turn the control 8 to the left hand limit The connection of the hot air exits C through the grills B of the canopy and to adjacent rooms can be carried out using flexi ble metal tubes To use this option you must take off the covers over the air exits C of the apparatus Whatever type of hot air exit you choseit is advisable to install grills in the uppe...

Страница 3: ...When wood is slowly burnt tar and other organic vapours are formed which when combined with air humidity form soot Soot vapours can condense if the chimney walls are cold If the soot catches fire then very high flames are produced Any accumu lation of soot has to be cleaned As the accumulation of soot depends on so many different things it is very difficult to say when the chimney has to be cle an...

Страница 4: ...he pipe joins the brick chim ney f It is very important that the joins of the pipes are well sea led to cover any possible cracks which will allow air to enter The following procedure is to test that the chimney is water tight Cover the exit in the roof Put paper and wet straw in the lower part of the chimney and light them See if any smoke comes out of any possible cracks and seal them INCORRECT ...

Страница 5: ... Ventilators stopped If the temperature of the air for heating reaches approximately 50 degrees the THER MOSTAT starts up the ventilators at 750 revs per minute When the Compact C 4 is used it should be connected to the electricity system to prevent it from over heating Pilot light 8 on POSITION I COMFORTABLE The ventilators operate to gether at 875 revs per minute POSITION II STRONG The ventilato...

Страница 6: ...ormation of tar it isre commended to put the ashpan door handle at 90 degrees to allow plenty of air for combustion This situation should be maintained atthe beginning of lighting to get the stove and chimney to heat up quickly preventing the for mation condensation of tar soot It is vital Once the stove is hot the ashpan door should be closed Fig 15 Fig 16 B SECONDARY AIR The Compact C 4 stove ha...

Страница 7: ...e assembly and joining instructions C BAFFLE SECONDARY AIR COLLECTOR Dismantling See Fig 17 Slide the collector A forwards until the connection sleeves co me out of their fixings and the collector falls Instruction F 6 CLEANING D CLEANING OUT THE ASHES The Compact stove has an ashpan under the bottom of the stove To get rid of the ashes take the blind grill out using a protec tive glove using the ...

Страница 8: ...not situate it near inflammable walls or walls which ha ve any type of covering which could be damaged by high tempe ratures varnish paint etc 8 SAFETY 9 TECHNICAL SPECIFICATIONS Fig 20 Model Measurements mm C 4 70 Stove measurements mm Height 370 560 370 105 450 467 630 600 700 A B C D E Diamet er 175 200x200 5 6 10 900 Width Depth Kg Plate piping mm Works pipe mm Height m Kcal h Weight Chimney m...

Страница 9: ...om rear stove interior 25 Right lateral interior side cover 26 Right exterior side 27 Upper side glass fixing clamp 28 Secondary air collector 29 Operation pilot 30 Connection pilot 31 Right lateral grill 32 Switch 33 Ashpan door control 34 Ashpan door handle 35 Ashpan door knob 36 Grill position spring 37 Right ventilator protective screen 38 Thermostat support 39 Ashpan door 40 Ashpan door hinge...

Отзывы: