background image

The safety and performance of the C-4 stove will greatly de-

pend on its correct installation.

It is very important to install the stove correctly.

To ensure that your stove is installed correctly it is advisable

that this job is done by a professional.

Although the Compact C-4 stove gives out heat by radiation,

directly heating walls, ceilings etc. this is mainly done by forced air
convection thanks to the ventilators incorporated in the stove which
direct  the heat to the furthest parts of the room.

A. ASSEMBLY

To install the Compact C-4 stove you will first have to build a

chimney (“draught”) with suitable metal tubes until it is 1 metre abo-
ve the highest part of the roof.

If there is already a chimney, then the stove has to be installed

by extending the already existing chimney using a tube to join the
smoke exit of the apparatus to the existing chimney.

It is very important that the joints between the sections of the

chimney are well sealed.  (See fig. 11).

B. POSSIBILITIES OF A HOT AIR EXIT

(Fig. 2.)

EXIT THROUGH THE FRONT UPPER GRILL (A). Turn the

control 8 to the left hand limit.

EXITS THROUGH THE CANOPY (B) AND / OR TO OTHER

ADJACENT ROOMS.  Turn the control 8 to the left hand limit.

The connection of the hot air exits (C) through the grills (B) of

the canopy, and to adjacent rooms can be carried out using flexi-
ble metal tubes.

To use this option you must take off the covers over the air

exits (C) of the apparatus.

Whatever type of hot air exit you chose it is advisable to install

grills in the upper part of the canopy and in the lower part of the

14

2. INSTALLATION

1. PRESENTATION

1. Front
2. Hot air exit control
3. Primary air collector
4. Stove door handle
5. Stove inside side
6. Stove inside rear
7. Air entrance grill
8. Stove inside base
9. Ashpan door handle

10. Ashpan door
11. Ash emptying cover
12. Stove door
13. Exterior steel plate casing

1

2

3

4

5

6

7

8

9

10

11

7

12

13

Fig. 1

inset to allow the hot air to circulate around the inside of the stove
thus:

- bringing extra hot air to the room

- and preventing possible cracks in the covering 

HERGÓM has decorative grills of 25x20 and 50x20 cm which

can be supplied as optional extras.

1.  Chimney pipe
2.  Hot air exit to the room
3.  Grill
4.  Flexible metal pipe
5.  Metal clamp

6. Chimney collar
7. Hot air collar diameter 125
8. Hot air exit control
9. Hot air exit to the room

10. Cold air entrance from the room.

Fig. 2

1

2

3

4

8

6

9

10

10

2

3

4

5

7

8

9

Содержание Compact C-4

Страница 1: ...y directly INDUSTRIAS HERGÓM S A does not take any responsibility whatsoever for the dama ges caused by or resulting from alterations to its products that have not been authorised in wri ting or for defective installations Furthermore it reserves the right to modify its finished products without prior war ning Industrias Hergom S A with registered offices in Soto de la Marina Cantabria Spain of fe...

Страница 2: ...H THE CANOPY B AND OR TO OTHER ADJACENT ROOMS Turn the control 8 to the left hand limit The connection of the hot air exits C through the grills B of the canopy and to adjacent rooms can be carried out using flexi ble metal tubes To use this option you must take off the covers over the air exits C of the apparatus Whatever type of hot air exit you choseit is advisable to install grills in the uppe...

Страница 3: ...When wood is slowly burnt tar and other organic vapours are formed which when combined with air humidity form soot Soot vapours can condense if the chimney walls are cold If the soot catches fire then very high flames are produced Any accumu lation of soot has to be cleaned As the accumulation of soot depends on so many different things it is very difficult to say when the chimney has to be cle an...

Страница 4: ...he pipe joins the brick chim ney f It is very important that the joins of the pipes are well sea led to cover any possible cracks which will allow air to enter The following procedure is to test that the chimney is water tight Cover the exit in the roof Put paper and wet straw in the lower part of the chimney and light them See if any smoke comes out of any possible cracks and seal them INCORRECT ...

Страница 5: ... Ventilators stopped If the temperature of the air for heating reaches approximately 50 degrees the THER MOSTAT starts up the ventilators at 750 revs per minute When the Compact C 4 is used it should be connected to the electricity system to prevent it from over heating Pilot light 8 on POSITION I COMFORTABLE The ventilators operate to gether at 875 revs per minute POSITION II STRONG The ventilato...

Страница 6: ...ormation of tar it isre commended to put the ashpan door handle at 90 degrees to allow plenty of air for combustion This situation should be maintained atthe beginning of lighting to get the stove and chimney to heat up quickly preventing the for mation condensation of tar soot It is vital Once the stove is hot the ashpan door should be closed Fig 15 Fig 16 B SECONDARY AIR The Compact C 4 stove ha...

Страница 7: ...e assembly and joining instructions C BAFFLE SECONDARY AIR COLLECTOR Dismantling See Fig 17 Slide the collector A forwards until the connection sleeves co me out of their fixings and the collector falls Instruction F 6 CLEANING D CLEANING OUT THE ASHES The Compact stove has an ashpan under the bottom of the stove To get rid of the ashes take the blind grill out using a protec tive glove using the ...

Страница 8: ...not situate it near inflammable walls or walls which ha ve any type of covering which could be damaged by high tempe ratures varnish paint etc 8 SAFETY 9 TECHNICAL SPECIFICATIONS Fig 20 Model Measurements mm C 4 70 Stove measurements mm Height 370 560 370 105 450 467 630 600 700 A B C D E Diamet er 175 200x200 5 6 10 900 Width Depth Kg Plate piping mm Works pipe mm Height m Kcal h Weight Chimney m...

Страница 9: ...om rear stove interior 25 Right lateral interior side cover 26 Right exterior side 27 Upper side glass fixing clamp 28 Secondary air collector 29 Operation pilot 30 Connection pilot 31 Right lateral grill 32 Switch 33 Ashpan door control 34 Ashpan door handle 35 Ashpan door knob 36 Grill position spring 37 Right ventilator protective screen 38 Thermostat support 39 Ashpan door 40 Ashpan door hinge...

Отзывы: