HP105 Plasma arc voltage height controller
第
- 20 -
页 共
23
页
Parameter setting screen, hold UP and DOWN at the same time more than three seconds, into the
implicit parameter setting.
NO.
parameter name
Parameter meaning
Factory
Settings
1
MAX_PWM
Maximum pulse width
120
2
MIN_PWM
minimum pulse width
30
3
IHS_UP
initial positioning pulse
width
100
4
IHS_DOWN
initial position by pulse
width
100
5
HAND_PWM
Up and down pulse width
manually
120
6
ARCV_ERR
Arc voltage protection
scope
020
7
EN_BREAK
brake can make
01
8
PWM_AMP
Automatic sensitivity
005
9
UP_BREAK
Increase reverse braking
time
030
10
DN_BREAK
By reverse braking time
080
11
EMG_LIFT
Promotion time of
emergency
020
12
EMG_ PWM
Emergency pulse width
120
13
ADJ_RANGE
Arc pressure intelligent
adjusting range
015
14
ADJ_STEP
The size of arc voltage
intelligent adjustment
002
15
ADJ_EN
Arc pressure intelligent
effective adjustment
000
16
ARC_ACC
Arc pressure precision
01
17
PEI_EN
Perforation signal can
make
01
18
AUTO_UP
Broken arc cutting torch
when hoisting height
10
19
ERR_STOP
Arc pressure anomalies can
stop making
00
20
DELAY_IN
When the arc rolling access
05
21
RESET(18)
Restore the factory value
00