electrode is negative. When process the cutting, the arc voltage
absolute value is usually higher than 100V. If so, the voltage must
be divided in order to process the control in the controlling circuit.
ATTN: the voltage that put into the height controller is negative.
If the polarity is connected in reverse, the Height Auto-adjusted is
not available.
The controller built-in isolation stars platen default input 1:1 Actual
arc voltage (when the partial pressure ratio of 100: 1) 1. For some comes
with 50: 1 non-isolated sub-plate plasma can set the input of 50: 1 low
pressure (in this case the partial pressure ratio of 2: 1).
Enter the arc voltage is set by DIP switch on the back of the controller to
set:
DIP switch to on: Input 1: 1 actual arc voltage.
DIP switch to the next: Enter 50: 1 arc voltage dividing.
初始定位介绍
本公司的调高器设计有两种定位方式,有条件的情况
下,推荐同时使用,以提高定位的可靠性。
3.4 IHS introduction
Set the input
voltage arc