TR8100V Thermos t at I nstructions
ver 1.0
LCD symbols
See overleaf for further setting up information
Setting the clock and day of the week
This thermostat is fitted with a real time clock. It is essenti al that the clock time and day are set accurately if you requir e your programmed events
1) Touch the time display and the time will start flashing. Use the up and down arrows to set the time.By holding the arrow down the time will change faster.
2) Press to move to the Day setting and use the u p and down arrows to get to the correct day.
3) Press to store and exit.
to start on time. To set follow the steps below:
Page1
The buttons are locked
Heating is turned on
Automatic mode,
Manual mode
executes the programmed schedules
The floor sensor is not being read by the thermostat
Err
Temporary temperature override
Frost protection activated
AUTO
Override
Symbol
Symbol
Event
Event
Program number
Economy temperature
Comfort temperature
Configuration Menu
To enter into the setting menu please follow the steps below:
Step 3, Use the up and down arrows to adjust the sensor selecti on which is Menu 01(Air sensing;Air and Floor, or Floor only)
Step 4, Press to move to the next Menu and once y ou have all the menu options set,
Setp 5, Press to accept and store.
Step 1, Turn the thermostat off by pressing ;
Step 2, Press , you will then see menu 01.
POWER
NEXT
NEXT
DONE
DONE
MENU
This thermostat is a combination model which allows you
to choose 3 different modes.
A mode = Air Sensing Only(Has built i n sensor)
AF mode = Air & Floor sensing( Floor probe must be installed)
F mode = Floor Sensing(Floor probe mus t be installed)
Menu #
01
Mode/Sensor selection
Switching Differential
Air Temp Calibration
Floor Temp Calibration
Temperature Readout
(AF mode only)
Maximum Floor Temp
( AF mode only)
Temperature Format
Clock Format
24 (default), 12- hour or 24-hour clock format
02
03
04
05
06
07
08
09
10
Feature
Explanation
Adjustment
1 °C, 2°C....10°C ( 1°C by default)
-1 °C = decrease 1 °C , 1 °C = increase 1 °C ...
-1 °C = decrease 1 °C , 1 °C = increase 1 °C ...
A= to show air temperature, F=to show floor temperature,
A--F = to show both in 5 second intervals
20 °C~ 40 °C (40 °C by default)
C or F
A, AF, F
(press up & down buttons to adjust)
The number of degrees difference before switching.
The default is 1°C which means the thermostat will switch
the heating on 0.5°C below the set temperature and will turn
it off 0.5°C above the set temperature.With a 2°C differential
the heating will switch on 1°C below the set temperature
and will switch off 1°C above the set temperature.
This is to recalibrate the air temperature if required.
This is to recalibrate the floor temperature if required.
This gives you the option to show the Air Temperature,
Floor Temperature or to show both Air & Floor at intervals.
This is to protect the floor surface.
This alows the temperautre to be set to show °C or °F.
You can select the clock to show in either 12 or 24 hour time
5+2 / 7 Day Mode
This allows you to program either 5 days at once, then the
2 days of the weekend separately, or a full 7 days at the
same time or 7 days separately
Frost Protection
on= activated, off= deactivated
01 = 5+2 day programmable
02 = 7 day programmable
This is to avoid your room temperature going below 5 °C